Hierarchical VMD parameter selection for short-term HVAC load forecasting: A compact TCN-LSTM implementation
Liang Yin, YouSong Zhang, Ruiqi Zhang, Cheng Xu, Jiewen Deng, Weiqi Zhu, Lu Dong
Key points
From the paper's conclusion- Therefore, the procedure fixed VMD parameters without using test targets but did not establish an RMSE advantage over the reference pair.
Abstract
Variational mode decomposition (VMD) separates heating, ventilation, and air-conditioning (HVAC) load into narrower-band signals, but the number of modes and the bandwidth-penalty parameter must be selected without using test-set outcomes. We evaluated a diagnostic-guided selection procedure using a multichannel temporal convolutional network (TCN) with long short-term memory (LSTM). The dataset comprised 2208 hourly observations from Wuhan Cigarette Factory in summer 2024. For each target, VMD used the preceding 168 h; the final 24 values from each mode served as TCN-LSTM input. Training-only diagnostics screened 64 parameter pairs using range-normalized reconstruction error, the coefficient of variation in mode-specific sample entropy, and the first-mode energy ratio. Sixteen pairs met the criteria. The eight lowest-scoring pairs formed a diagnostic shortlist, which was evaluated with seed 42 and then across seeds 42–44. The selected pair, K=7 and α=1500, yielded validation and test root-mean-square errors (RMSEs) of 2.113±0.079 and 2.253±0.161 kW across seeds 42–44 and 42–46, respectively. On the test segment, the reference 5,2000 and minimum-J admissible 8,1000 pairs yielded RMSEs of 2.243±0.094 and 2.285±0.161 kW, respectively. VMD-transformer with bidirectional LSTM (VMD-transformer-BiLSTM) and VMD-TCN-LSTM yielded 2.185±0.062 and 2.253±0.161 kW, respectively; Diebold–Mariano tests showed no consistent squared-loss difference across seeds. VMD-TCN-LSTM used 14 961 parameters, 73.8% fewer than VMD-transformer-BiLSTM. Excluding preprocessing and data handling, its single-sample network forward-pass time was 0.285±0.014 ms. Across 231 diagnostic-weight combinations, five pairs were selected, with seed-42 validation RMSE spanning 2.038–2.063 kW. Therefore, the procedure fixed VMD parameters without using test targets but did not establish an RMSE advantage over the reference pair.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A VMD–Bayesian-Optimized XGBoost–BiLSTM Hybrid Model for Short-Term Load ForecastingElectronics · 2026
- A Multi-Channel Δ-BiLSTM Framework for Short-Term Bus Load Forecasting Based on VMD and LOWESSElectronics · 2025
- Short-term load forecasting based on the improved bi-directional long short-term memory modelInternational Journal of Electrical Power & Energy Systems · 2026
- Lightweight Reservoir Fusion Architecture for Multi-Horizon Load Forecasting in Power SystemsSmart Grids · 2026
- CVGKAN: A Hybrid Short-Term Load Forecasting Framework Based on Cascaded Signal Decomposition and GRU-KANElectronics · 2026
- Short-Term Load Forecasting Under Extreme Temperatures Based on Transformer–TCN and BiGRU Residual CorrectionProcesses · 2026