First evaluation of the runaway electron measurement capability of the radial gamma-ray spectrometers diagnostic at ITER.
M Nocente, A Ciurlino, A Dal Molin, F J Artola, B Coriton, G Croci, S Fugazza, G Gorini,
Department of Physics, University of Milano-Bicocca, Milan 20126, Italy. · ITER Organization, St Paul Lez Durance Cedex 13067, France.
Key points
From the paper's conclusion- We identify the post-disruption background due to the residual activation of the first wall as the primary modeling uncertainty, which, if negligible, could lower IRE,min detected by the RGRS system by up to a factor of ≈10, as expected for early DT experiments, when tritium will be injected in ITER for the first time.
Abstract
Tokamak disruptions and the resulting multi-megampere beams of relativistic runaway electrons (REs) present severe machine-protection risks for ITER. While shattered pellet injection serves as the primary line of defense for mitigation, a robust diagnostic system is mandatory to evaluate the RE current and energy. This paper provides the first assessment of the RE measurement capabilities of the radial gamma-ray spectrometers (RGRS) in ITER 15 MA deuterium-tritium (DT) scenarios. Under steady-state conditions, the combined three-detector RGRS system is sensitive to RE currents as low as IRE,min ≈ 60 kA for neon densities of ≈1020m-3, which is within the requirement to make measurements every 10 ms and for currents down to 5% of the plasma current, i.e., 750 kA for a 15 MA full-power DT scenario, as well as within the desired safety limit of 150 kA. However, when accounting for the highly dynamic, millisecond-scale growth of the RE beam in realistic DT disruption scenarios, the practical detection threshold shifts into the 500 kA-4 MA range, with most scenarios having a threshold between 1 and 2 MA. We identify the post-disruption background due to the residual activation of the first wall as the primary modeling uncertainty, which, if negligible, could lower IRE,min detected by the RGRS system by up to a factor of ≈10, as expected for early DT experiments, when tritium will be injected in ITER for the first time. We also show that a single, tangential detector with a design similar to those of the RGRS could further lower the sensitivity to IRE,min by a factor of ≈60 using the current assumption about the background.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Damage and Mitigation of Runaway Electrons in ITER Plasma-Facing ComponentsEnergies · 2026
- Simulation of runaway electron generation in the Day-0 scenario of DTTFusion Engineering and Design · 2025
- Operational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITERPlasma Physics and Controlled Fusion · 2026
- 3D modelling of runaway electron deconfinement by MHD instabilities in ITER mitigated disruptions: from avalanche to terminationNuclear Fusion · 2026
- Effect of scrape-off losses and current flattening on runaway electron dynamics in ARCarXiv · 2026
- Implementation and verification of the avalanche source in a 3D full-f particle-in-cell model of relativistic electrons for studies of tokamak disruptionsPhysics of Plasmas · 2026