Pulsatile non-Newtonian blood flow in arterial aneurysms: Parametric hemodynamic characterization using the finite volume incompressible lattice Boltzmann method
Akshay Dongre, Song-Lin Yang
Key points
From the paper's conclusion- Pulsatile non-Newtonian blood flow is simulated using the finite volume incompressible lattice Boltzmann method (FV-iLBM), which captures shear-rate-dependent viscosity through the Carreau model while recovering the incompressible Navier–Stokes equations on unstructured meshes without an iterative pressure–velocity coupling.
Abstract
Arterial aneurysms pose a significant public health challenge, with their rupture leading to life-threatening cardiovascular complications. The present study investigates the interplay between aneurysm size, pulsatile flow conditions (Reynolds and Womersley numbers), blood rheology (Carreau number), and key hemodynamic indices—time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and reverse flow fraction (RFF)—to characterize the hemodynamic environment associated with aneurysm progression and rupture risk. Pulsatile non-Newtonian blood flow is simulated using the finite volume incompressible lattice Boltzmann method (FV-iLBM), which captures shear-rate-dependent viscosity through the Carreau model while recovering the incompressible Navier–Stokes equations on unstructured meshes without an iterative pressure–velocity coupling. Increasing Reynolds number raises peak TAWSS and intraluminal pressure while reducing the wall area with OSI >0.20 from 64% to 2.65% (Re=50–200)—exposing competing inertial and oscillatory pathways whose dominance shifts with Re. Higher Womersley numbers amplify shear-layer oscillations and separation dynamics, whereas lower Carreau numbers sustain an elevated effective viscosity that suppresses vortical structures and lowers OSI. Aneurysm size critically modulates these effects: larger aneurysms generate a peak RFF roughly twice that of smaller lesions (∼16% vs ∼7.5%), a distal peak TAWSS about 16% higher, and an 18% collapse of centerline velocity, whereas smaller aneurysms exhibit higher local OSI peaks. By resolving these competing mechanisms, the study demonstrates that no single index captures aneurysm rupture risk and that geometric growth simultaneously escalates peak mechanical stress, expands the atheroprone wall footprint, and elevates the wall pressure loading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nanoparticle-Based Drug Delivery for Hemodynamic Disruption in Idealized Aneurysmal ArteriesJournal of Advances in Mathematics and Computer Science · 2026
- Transport regimes in pulsatile stenotic flowPhysics of Fluids · 2026
- Machine Learning-Based Reduced-Order Prediction of Rupture-Related Hemodynamics in Cerebral Aneurysms with Surface Blebs: A Pilot Study.Journal of imaging informatics in medicine · 2026
- Fully discrete second-order energy-stable HDG method for Carreau-type blood flows with applications to three-dimensional aneurysm hemodynamicsComputer Methods in Applied Mechanics and Engineering · 2026
- A Comparative Analysis of Stent Performance in Aneurysm: Impact of Newtonian and Non-Newtonian Flow DynamicsSciEn Conference Series Engineering · 2026
- Hemodynamic characteristics at rupture sites of middle cerebral artery aneurysms: a CFD study with intraoperative correlation.Frontiers in neurology · 2026