Impact of layout configurations on wake interactions and performance of dual vertical-axis wind turbines in offshore wind farm
Redili Yushan, Rui Zhang, Limin Kuang, Zhihao Zhang, Huan Ping, Dai Zhou
Key points
From the paper's conclusion- This study employs unsteady Reynolds-averaged Navier–Stokes simulations, comprising 49 two-dimensional (2D) cases and 11 selected three-dimensional (3D) cases, to investigate the power performance and wake interactions of tandem DVAWT configurations across streamwise spacing LS/D ∈ [3, 9] and lateral offset LH/D ∈ [0, 3].
Abstract
While the vast potential of offshore wind energy is widely recognized, balancing spatial efficiency with structural costs remains a persistent obstacle. Leveraging their inherent suitability for narrow arrangements, dual vertical-axis wind turbine (DVAWT) systems offer a potential approach to offshore wind farm layout design. This study employs unsteady Reynolds-averaged Navier–Stokes simulations, comprising 49 two-dimensional (2D) cases and 11 selected three-dimensional (3D) cases, to investigate the power performance and wake interactions of tandem DVAWT configurations across streamwise spacing LS/D ∈ [3, 9] and lateral offset LH/D ∈ [0, 3]. The 3D results show that the counter-rotating configuration suppresses the lateral wake deflection of individual turbines, producing an approximately laterally symmetric composite wake with a pronounced central acceleration channel. This creates a characteristic low–high–low velocity distribution: the normalized gap velocity reaches 0.988 at X/D = 1, compared with 0.488 in the rotor-wake regions, defining the nonuniform inflow environment for downstream units. Within the 2D survey, LH emerges as the dominant layout parameter, while LS plays a secondary role. As LH increases, the downstream unit transitions through three characteristic inflow states—full immersion, differential immersion, and bypass recovery—producing a nonmonotonic ridge–valley power distribution. The best-performing 2D configuration (LS/D, LH/D) = (3, 3) yields a 6.7% increase in normalized overall power relative to the operating isolated DVAWT units. The same configuration also gives the highest overall power among the 11 selected 3D cases, although its normalized overall power remains below unity at 0.8876. The 3D vortex visualizations and turbulent kinetic energy distributions further show that aligned configurations exhibit stronger interaction between the unit wakes, whereas staggered configurations reduce upstream wake exposure at the downstream rotors and maintain more spatially separated wake structures. These findings provide physical insight into tandem DVAWT wake interactions and inform the assessment of compact layouts for offshore applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Are vertical-axis wind turbines a scientific mirage or the future of offshore wind energy? A critical perspective a century after Darrieus’ patentRenewable and Sustainable Energy Reviews · 2026
- Aerodynamic-aeroacoustic co-design and multi-objective optimization of vertical-axis wind turbines: a critical review of dynamic stall, flow control, and data-driven methodsFrontiers in Mechanical Engineering · 2026
- Rotor configuration effects on coupled aero-hydro-mooring dynamics of spar-type floating vertical axis wind turbinesEnergy · 2026
- Development and validation of an improved double-multiple streamtube model for predicting performance of H-type straight-bladed vertical axis wind turbinesPhysics of Fluids · 2026
- Yaw Wake Steering for Simultaneous Power Maximization and Component-Level Fatigue Balancing in Offshore Wind FarmsMachines · 2026
- Wind Farm Micrositing Considering the Potential of Active Yaw ControlJournal of Marine Science and Engineering · 2026