Physics of Fluids

Influence of back-blade structure on axial force and flow characteristics of a centrifugal pump

Lulu Zhai, Xiang Li, Jia Guo, Jintao Liu, Zuchao Zhu

Key points

From the paper's conclusion
  • Notably, axial force presents a non-monotonic hump-shaped variation with flow rate, peaking at 0.75Qd for fully aligned back-blade impellers.

Abstract

Axial force critically affects the operational stability, bearing load and service life of centrifugal pumps, and back blades on the rear shroud are a widely adopted effective measure for axial-force mitigation. This work systematically explores the influences of curved back-blade configurations on pump hydraulic performance, axial-force variation, and internal flow structures via experiments coupled with steady and unsteady numerical simulations. One prototype impeller with balance holes and four curved back-blade impellers are tested under five flow conditions from 0.25Qd to 1.25Qd. The numerical method is validated against experimental data, with maximum relative errors of 3.25% for pump head and 8.51% for axial force. Eight newly designed impellers with varied back-blade counts and phase offsets are further simulated to analyze axial-force-flow characteristics. Curved back blades raise pump head but slightly reduce hydraulic efficiency. Notably, axial force presents a non-monotonic hump-shaped variation with flow rate, peaking at 0.75Qd for fully aligned back-blade impellers. The phase offset between main and back blades is identified as the dominant factor governing the hump. Aligned back blades intensify rotor–stator interaction, drive the primary vortex to precess toward the front-shroud clearance, amplify leakage, and induce a sharp front-shroud pressure drop, while phase-offset back blades suppress such interaction and eliminate the hump. These findings provide physical insight and practical guidance for back-blade optimization in centrifugal pump axial-force control.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of back-blade structure on axial force and flow characteristics of a centrifugal pump — Science Skim