Measurement of a lepton-lepton electroweak reaction (MOLLER) spectrometer magnet-Magnetic field measurement and analysis at Jefferson lab.
P K Ghoshal, B Eng, I Gildea, S Gopinath, M P Dion, B U Don, J Mammei, R Rajput-Ghoshal,
Magnet Group, Experimental Nuclear Physics Division, Jefferson Lab, Newport News, Virginia 23606, USA. · Detector Support Group, Experimental Nuclear Physics Division, Jefferson Lab, Newport News, Virginia 23606, USA.
Key points
From the paper's conclusion- The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC.
Abstract
The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC. Scheduled to operate over a three-year period, the experiment relies on five water-cooled toroidal magnets-each with seven-fold symmetry and unique geometry-engineered to focus scattered particles. These magnets generate the magnetic field necessary to separate Moller-scattered electrons from elastically scattered protons within the liquid hydrogen target. To meet physics requirements for the experiment, the field in the bore of each magnet must be low enough to not interfere with the scattered protons and generate unwanted backgrounds downstream. This paper presents an engineering-focused evaluation of the magnetic field mapping process, comparing the measured fields with the design specifications and the simulated fields in the bore. The resulting field maps are intended for use in GEANT4 simulations, where precision is critical due to the challenges of low-field measurements. The field analysis will quantify the differences between the ideal and measured magnetic fields. The final field-mapping data will then be used to verify how well the original engineering assumptions performed in generating field inputs for "ee and ep" tracking simulations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The SHMS 11 GeV/c Spectrometer in Hall C at Jefferson LabODU Digital Commons (Old Dominion University) · 2026
- Ground Transmitter Waves in the Magnetosphere and Their Role in Electron ScatteringJournal of Geophysical Research Space Physics · 2026
- Magnetic field sensitivity study of an X-ray GEM diagnostic for RFX-mod2Journal of Instrumentation · 2026
- Characterization of spectral slit functions of magnetic particle spectrometers.The Review of scientific instruments · 2026
- The next-generation magnetic recoil spectrometer for measurements of the absolute neutron spectrum at Pacific Fusion's demonstration system.The Review of scientific instruments · 2026
- Towards the experimental assessment of exposure to extremely low frequency magnetic field.Physics in medicine and biology · 2026