High-pressure-ratio vacuum sealing by a perturbed free-vortex aerodynamic window.
Hiroshi Imao, Kazumasa Takahashi, Yasuto Miyake, Kazuyuki Oyamada, Hiroki Okuno, Kazuhiko Horioka
RIKEN Nishina Center for Accelerator-Based Science, Wako, Saitama 351-0198, Japan. · Department of Electrical, Electronics and Information Engineering, Nagaoka University of Technology, Nagaoka, Niigata 940-2188, Japan.
Key points
From the paper's conclusion- These results show that, in a low-gas-flow-rate regime while keeping the supply-plenum pressure below atmospheric pressure, perturbed free-vortex operation can realize a high sealing pressure ratio that cannot be obtained under the conventional matched condition.
Abstract
In this study, we investigated a perturbed free-vortex operating concept for enhancing the sealing pressure ratio phigh/plow of a free-vortex aerodynamic window by intentionally shifting the flow away from the conventional matched free-vortex condition. A compact free-vortex aerodynamic-window assembly with a 15-mm-diameter open beam passage was designed, fabricated, and tested using air under low-gas-flow-rate conditions while keeping the supply-plenum pressure below atmospheric pressure. Under the conventional matched condition, the pressure ratio was limited to about 5 at phigh = 9.1 kPa, whereas perturbed free-vortex operation increased it to about 70 and, in a lower-flow configuration with stronger low-pressure-side evacuation, to about 200. The obtained pressure ratios, the response to diffuser-geometry changes, and the internal pressure distributions showed good agreement with computational fluid dynamics simulations, suggesting that the performance enhancement was accompanied by reorganization of the internal flow structure. Measurements with Ar and He and a design-map evaluation of two free-vortex aerodynamic windows connected in series further indicated the extendability of the concept to other gases and multistage configurations, with an estimated overall pressure ratio of about 4550 for the two-stage configuration. These results show that, in a low-gas-flow-rate regime while keeping the supply-plenum pressure below atmospheric pressure, perturbed free-vortex operation can realize a high sealing pressure ratio that cannot be obtained under the conventional matched condition. This approach is promising for accelerator gas targets, gas strippers, and other high-pressure-ratio vacuum-sealing applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation of flow-directed vortex on penetration characteristics of transverse injection of multiphase fuelPhysics of Fluids · 2026
- Research on Contact Performance and Friction Force of VL Seal of Aviation Actuator Under High Pressure ConditionsLubricants · 2026
- Spectral analysis of wall-pressure fluctuations in electronic expansion valvesPhysics of Fluids · 2026
- From cavitating flow to vibroacoustic response in a deflector jet servo valve pilot stage under wide temperature and back pressure conditionsPhysics of Fluids · 2026
- Experimental study of air-pocket-induced transient pressures in pipelinesJournal of Hydraulic Research · 2026