From the paper's conclusion- We tested the pipeline on 3D digital twins built from MR images acquired in n = 8 swine with chronic infarction, by performing a subject-specific personalization of each model per tissue type (i.e., scar, border zone, and healthy) and tuning the key parameters (e.g., action potential duration, excitability, and wave speed) from recorded endocardial bipolar voltage maps and intracardiac electrogram
Abstract
The computational efficiency of contemporary multi-scale digital twins used to investigate cardiac arrhythmia is often hindered by the equation system complexity, while the accuracy of predictions depends on the calibration of model parameters and their intricate non-linear relation. Here we employed a robust pipeline for fast simulations of scar-related ventricular tachycardia (VT) inducibility using an efficient Lattice-Boltzmann Method with GPU-based accelerated code. We tested the pipeline on 3D digital twins built from MR images acquired in n = 8 swine with chronic infarction, by performing a subject-specific personalization of each model per tissue type (i.e., scar, border zone, and healthy) and tuning the key parameters (e.g., action potential duration, excitability, and wave speed) from recorded endocardial bipolar voltage maps and intracardiac electrograms. We first validated the VT simulation outcome by precisely replicating the stimulation protocol and pacing site used in the animal studies. Our results demonstrated very good agreement between the experiment and simulated VT outcome for personalized model parameters using subject-specific values, compared to a poor outcome when parameters were tuned from average values from all cases. Second, we performed a comprehensive in silico study where the stimulation was delivered from 10 000 virtual endocardial locations and found a strong dependence of VT (non)/-inducibility per case on the stimulation site. Simulating 10 s of sustained VT induced on a 3D model comprising 1.2 million cubic voxels (0.7 mm edge size) took 30 min on a laptop using GPU, underlying the computational tractability of our pipeline and its potential clinical translation to predict infarct-related VT risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Personalized Digital Twins in Scar‐Dependent Ventricular Tachycardia: Mechanistic Insight, Clinical Translation, and the Limits of Computational PrecisionJournal of Interventional Cardiology · 2026
- Accounting for uncertainty in computational models of ventricular tachycardia improves ablation guidance.Nature cardiovascular research · 2026
- Predicting in-silico ventricular tachycardia induction on fuzzy cardiac digital twins.Medical & biological engineering & computing · 2026
- The Hodgkin-Huxley-Katz Prize Lecture: Heart digital twins: A new paradigm in arrhythmia medicine.The Journal of physiology · 2026
- An image-based framework for in silico trials of ablation strategies in scar-related ventricular tachycardiabioRxiv · 2026
- A High-Fidelity Cardiac Digital Twin for Assessing Rate-Dependent Responses: A Comparative Multi-scale Study of TT2 and Tomek Models in Stratified 3D VentriclesarXiv · 2026