Nanotechnology and Precision Engineering

Toward real-time anomaly detection in direct laser interference patterning using autoencoder analysis of plasma emission signals

Wei Wang, Marcelo Daniel Sallese, Bogdan Voisiat, Marcos Soldera, Christoph Steiger, Dominik Britz, Andrés Fabián Lasagni

Key points

From the paper's conclusion
  • The proposed framework demonstrates that compact photodiode-based plasma emission monitoring, Gini-based surface labeling, and lightweight AE modeling can be combined to assess DLIP surface quality from process signals.

Abstract

Direct laser interference patterning (DLIP) is a high-precision surface engineering technique with strong potential for scalable industrial surface functionalization. However, ensuring consistent pattern quality requires monitoring strategies that are sensitive to subtle process deviations. This study introduces a lightweight autoencoder (AE)-based framework for morphology-referenced anomaly detection in DLIP using time-resolved plasma emission signals acquired with an off-axis photodiode setup. Surface morphologies are characterized by confocal microscopy and scanning electron microscopy, and a Gini coefficient-based homogeneity index is used to generate binary reference labels—“healthy” and “non-healthy”—for signal classification. The signals are segmented into local analysis windows, transformed into frequency-domain spectra, linked to these morphology labels, and used to train the AE only on spectra from “healthy” processing conditions. Three reconstruction-error metrics, namely Euclidean distance, Manhattan distance, and Mahalanobis distance (MahaD), are systematically compared. Among them, MahaD achieves the best performance, with 91% classification accuracy and 95% sensitivity for detecting nonhomogeneous surface formation, reflecting the benefit of covariance-aware scoring for correlated spectral features. The proposed framework demonstrates that compact photodiode-based plasma emission monitoring, Gini-based surface labeling, and lightweight AE modeling can be combined to assess DLIP surface quality from process signals. As a proof-of-concept study, it establishes a methodological foundation for future inline plasma-based process monitoring and for closed-loop quality control strategies after broader validation in industrial applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Toward real-time anomaly detection in direct laser interference patterning using autoencoder analysis of plasma emission signals — Science Skim