Shape-optimized Model-based Reconstruction Algorithm for Radiacoustic Imaging.
Prabodh Kumar Pandey, Omprakash Gottam, Kristina Bjegovic, Gilberto Gonzalez, Yong Chen, Liangzhong Xiang
Dept. of Radiological Sciences, University of California, Irvine, CA, 92697, USA. · Dept. of Electronics and Communications, Koneru Lakshmaiah Education Foundation, Hyderabad-500075, Telangana, India.
Abstract
We present a shape-optimized model-based (SOMB) reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct the approximate dose-region boundary using a parametric level set-based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a significantly better-constrained one. We validate this methodology through computational studies and experiments using clinical X-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with 3-25% improvement in correlation coefficients across different imaging settings-more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- View optimization in Computed TomographyarXiv · 2026
- Physics-Guided Gaussian Process Mapping of Strong-Gradient Radiation Fields from Mobile Robot Surveys: The Role of Sampling Geometry.Sensors (Basel, Switzerland) · 2026
- Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CTarXiv · 2026
- SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT ReconstructionarXiv · 2026
- OX-NeRF: 3D X-ray Tomography Reconstruction from Sparse Views Using Implicit Neural RepresentationarXiv · 2026
- Learned proximal gradient flow matching for limited-angle CT reconstruction.Physics in medicine and biology · 2026