X-ray-pump, speckled optical-probe transient grating spectroscopy at a hard-x-ray free electron laser.
T M Hutchinson, C P McGuire, I K Ocampo, J H Eggert, C Davis, E C Galtier, D Khaghani, N A Boiadjieva,
Lawrence Livermore National Laboratory, Livermore, California 94550, USA. · SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA.
Key points
From the paper's conclusion- Here, a platform for x-ray-pump, optical probe transient grating spectroscopy in averaged mode is described.
Abstract
Despite being a well-developed technique, transient grating spectroscopy has not been widely adapted to high-pressure condensed matter experiments. Here, a platform for x-ray-pump, optical probe transient grating spectroscopy in averaged mode is described. Improvements that may enable eventual single-shot assessments of thermal diffusivity for optically transparent materials at high pressure are detailed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A platform for two-color pump-probe x-ray Thomson scattering using the SPring-8 Angstrom Compact free-electron LAser.The Review of scientific instruments · 2026
- Single-shot third-harmonic spectral diagnostics for tender X-ray FEL pulses using a bent-crystal spectrometer.Journal of synchrotron radiation · 2026
- Quantifying sample heating by ablation-plasma x-rays in laser-driven shock experimentsarXiv · 2026
- Operator-level description of transient thermal grating dynamics across transport regimesOpen Transport · 2026
- Fourier-Transform Photothermal Spectroscopy with Transient-Lens DetectionarXiv · 2026
- Extensible open-source toolkit suite for studying second-harmonic generation: a case study of depleted pulsed Gaussian wave SHG.Applied optics · 2026