Shear Behavior of Grouped Long Studs in Novel Noncellular Steel–UHPC Joints of Hybrid Girder Continuous Rigid-Frame Bridge
Tao Sun, Hua Zhao, Chengjun Tan, Junde Hu, Yufeng Tao, Rong Liu, Lizhi Lu, Gaosi Wang,
Hunan University · Beijing Survey and Design Institute (China)
Key points
From the paper's conclusion- Accordingly, an empirical formula incorporating a reduction factor related to stud row number is proposed to predict the ultimate shear resistance of grouped long studs, showing good agreement with experimental results.
Abstract
Abstract To address the structural complexity and construction difficulties associated with conventional cellular steel–concrete joints (SCJs), this study proposes an innovative noncellular steel–ultrahigh-performance concrete (UHPC) joint (SUJ) for hybrid continuous girder bridges, in which headed studs are solely used to connect the steel box girder with monolithic UHPC grout. The proposed SUJ has been successfully implemented in the Yuanshui Bridge of the Yiyang–Changde Expressway ( G 55 17 ) in China, demonstrating its practical feasibility. Based on this joint configuration, push-out tests were conducted to investigate the shear behavior of long stud groups ( D 22 × 180 mm at 200-mm spacing), and the effects of stud diameter, aspect ratio, spacing, and configuration were systematically evaluated. Test results showed that all specimens failed by stud shank failure, and the grouped-stud arrangement resulted in an average 6.8% reduction in shear capacity per stud compared with single studs; meanwhile, increasing the aspect ratio from 3.6 to 8.2 led to a 6.6% decrease in shear capacity. Although denser arrangements using smaller diameter studs achieved comparable total shear resistance at similar shear areas, the elastic shear stiffness per stud of grouped studs was significantly reduced, and the interfacial slip between steel beams and UHPC blocks failed to satisfy the ductility requirement of current standards. Parametric analysis further confirmed that stud diameter plays a dominant role in shear capacity, whereas reduced stud spacing and increased stud row number adversely affect both shear capacity and ductility. Accordingly, an empirical formula incorporating a reduction factor related to stud row number is proposed to predict the ultimate shear resistance of grouped long studs, showing good agreement with experimental results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental investigation and theoretical analysis of hybrid notch-screw shear connectors used in timber-UHPC composite structuresEngineering Structures · 2026
- Numerical Investigation of the Shear Performance of Large-Diameter Hinged-Bolt Connectors in Steel–UHPC Composite BeamsBuildings · 2026
- Interface shear behaviour of ultra-high performance concrete under combined shear and lateral loadsEngineering Structures · 2025
- Research on the calculation method of flexural bearing capacity of wet joints of prefabricated concrete bridge beams based on the strut and tie modelAdvances in Bridge Engineering · 2026
- Flexural Behavior and Continuity Assessment of Precast UHPC One-Way Slabs with Post-Cast JointsSymmetry · 2026
- Investigation of direct shear behavior at UHPC interfaces incorporating high-strength steel lap jointsStructures · 2025