High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure
Jean-Pierre Frat, J. Quenot, Christophe Guitton, Rémi Coudroy, Arnaud Gacouin, Julio Badie, Alexandre Demoule, Damien Contou,
Inserm · Centre Hospitalier du Mans
Key points
From the paper's conclusion- Among patients with acute hypoxemic respiratory failure, the use of oxygen delivered through a high-flow nasal cannula did not significantly reduce mortality at day 28. (Funded by the French Ministry of Health and Fisher and Paykel Healthcare; SOHO ClinicalTrials.gov number, NCT04468126.).
Abstract
BACKGROUND: Data are needed on the effect of oxygen delivered through a high-flow nasal cannula, as compared with standard oxygen therapy, on intubation and mortality in patients with acute hypoxemic respiratory failure. METHODS: In this multicenter, open-label trial, we randomly assigned patients who had acute hypoxemic respiratory failure to receive high-flow-oxygen or standard-oxygen therapy. All the patients had a ratio of the partial pressure of arterial oxygen to the fraction of inspired oxygen of 200 or less, a respiratory rate of more than 25 breaths per minute, and pulmonary infiltrate on chest imaging. The primary outcome was death by day 28. RESULTS: A total of 1116 patients underwent randomization. Of these patients, 1110 (556 in the high-flow-oxygen group and 554 in the standard-oxygen group) were included in the analysis. Mortality at day 28 was 14.6% (in 81 of 556 patients) in the high-flow-oxygen group and 14.6% (in 81 of 554 patients) in the standard-oxygen group (difference, -0.05 percentage points; 95% confidence interval [CI], -4.21 to 4.10; P = 0.98). The incidence of intubation by day 28 was 42.4% (in 236 of 556 patients) in the high-flow-oxygen group and 48.4% (in 268 of 554 patients) in the standard-oxygen group (difference, -5.93 percentage points; 95% CI, -11.78 to -0.08). Serious adverse events (cardiac arrest or pneumothorax) occurred during spontaneous breathing in 13 patients (2.3%) in the high-flow-oxygen group and in 6 patients (1.1%) in the standard-oxygen group. CONCLUSIONS: Among patients with acute hypoxemic respiratory failure, the use of oxygen delivered through a high-flow nasal cannula did not significantly reduce mortality at day 28. (Funded by the French Ministry of Health and Fisher and Paykel Healthcare; SOHO ClinicalTrials.gov number, NCT04468126.).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-flow nasal cannula versus standard oxygen therapy for adult acute hypoxemic respiratory failure: a systematic review and meta-analysis with trial sequential analysis and GRADE assessment.BMC pulmonary medicine · 2026
- High-Flow Nasal Cannula in Adult Acute Care: Physiological Mechanisms, Clinical Evidence, and Persistent Misconceptions.Medicina (Kaunas, Lithuania) · 2026
- Efficacy of nasal high-flow therapy versus standard oxygen therapy in hypoxemic respiratory failure: a systematic review and meta-analysis of RCTS.Annals of medicine and surgery (2012) · 2026
- Predictors of High-Flow Nasal Oxygen Success in COVID-19 Respiratory Failure: A Retrospective Observational Cohort StudyCOVID · 2026
- High-Flow Nasal Cannula Versus Conventional Oxygen Therapy in Adults With De Novo Acute Hypoxemic Respiratory Failure: A Systematic Review and Meta-Analysis With Trial Sequential Analysis.Critical care medicine · 2026
- Nasal High‐Flow Therapy for Infants With Bronchiolitis Across Australia and New Zealand: A PREDICT and CIRCAN Clinician SurveyJournal of Paediatrics and Child Health · 2025