International Retrospective Observational Study of Continual Learning for AI on Endotracheal Tube Placement from Chest Radiographs.
Emma Chen, Agustina Saenz, Oishi Banerjee, Henrik Marklund, Xiaoman Zhang, Shreya Johri, Hong-Yu Zhou, Luyang Luo,
Department of Biomedical Informatics, Harvard Medical School, Boston, MA, USA. · Department of Computer Science, Stanford University, Stanford, CA, USA.
Key points
From the paper's conclusion- Despite using only 50 training data points from each hospital, continual learning surpassed traditional fine-tuning as a method for improving medical AI model generalization.
Abstract
BACKGROUND: Medical artificial intelligence (AI) models often underperform when deployed at new hospitals despite strong performance during development, creating a need for effective adaptation strategies that maintain institutional privacy. Continual learning (i.e., repeatedly retraining a model at each new hospital where it is deployed) can improve performance during and after deployment. METHODS: To determine whether continual learning could improve model performance across diverse clinical settings without requiring data exchange between hospitals or complex computational setups, we performed a retrospective study of a convolutional neural network model for endotracheal tube (ETT) assessment, comparing three deployment approaches (original model deployment, hospital-specific fine-tuning, and continual learning across hospitals). The study included 2313 intensive care unit chest radiographs across 23 hospitals spanning 12 countries and 5 continents, with 1 hospital held out for external validation. Participants were adults (≥18 years of age) with ETTs placed in 2021 (or earlier if a hospital found too few cases from 2021), identified through standardized key word searches in hospital systems and verified by radiology reports where available. Each hospital contributed approximately 100 anteroposterior radiographs, with 50 used for training, as well as associated deidentified reports and metadata. Each image was preprocessed by the contributing hospital to remove identifiable features and was independently reviewed and annotated by two radiologists. RESULTS: Continual learning models achieved a significantly lower average ETT-carina error of 10.58 mm (standard deviation [±SD], 12.98 mm), compared with 12.49 mm (SD±, 15.37 mm) for models fine-tuned only at their deployment hospital and 16.39 mm (±SD, 21.56 mm) for the original model. In addition, continual learning models outperformed the original model at all hospitals, and they outperformed models fine-tuned only at their deployment hospital at 21 of 22 hospitals. CONCLUSIONS: Despite using only 50 training data points from each hospital, continual learning surpassed traditional fine-tuning as a method for improving medical AI model generalization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Repurposing adult AI radiograph models for neonatal care through continual learning: an international multicentre study.Nature biomedical engineering · 2026
- Continual Learning in Medical Image Analysis: Appropriate Use and Lifecycle Governance.Journal of the Korean Society of Radiology · 2026
- PRAM: post-hoc retrieval augmentation adapts intensive care prediction models without retraining and can be shared across hospitalsmedRxiv · 2026
- Continual Learning in Medical Imaging: A Systematic Review of Methods, Applications, and Clinical Translation.Bioengineering (Basel, Switzerland) · 2026
- FIRST-ICU: a deep learning framework for multi-intervention prediction and risk stratification in critical care with cross-continental external validationEuropean Heart Journal · 2026
- Incremental Learning in Medical Imaging: A Comprehensive Survey of Deep Neural Network Advances and ChallengesIEEE Access · 2026