Klinische Padiatrie

Heparin Versus Saline for Locking Central Venous Access Devices in Pediatric Oncology: Results of a Multicenter Survey by the German Society for Pediatric Oncology and Hematology.

Nikola Hagedorn, Arne Simon, Ralf Knoefler, Sarah Schober, Susanne Holzhauer

Charité University Hospital Berlin, Pediatric Oncology and Hematology, Germany, Berlin. · Children's Hospital Medical Center, Paediatric Hematology and Oncology, Saarland, Germany, Homburg.

Key points

From the paper's conclusion
  • These findings highlight the need for harmonized, evidence-based recommendations and standardized prospective surveillance of central venous access device-associated complications.

Abstract

BACKGROUND: Long-term central venous access devices are essential for the treatment of children and adolescents with malignancies. As uniform evidence-based standards for their maintenance are lacking, practices vary among pediatric oncology centers within the German Society for Pediatric Oncology and Hematology network. The aim of this survey was to assess current central venous access device maintenance practices within centers of the German Society for Pediatric Oncology and Hematology. METHODS: In this multicenter cross-sectional survey, 76 German Society for Pediatric Oncology and Hematology centers in Germany, Austria, and Switzerland were asked about central venous access device maintenance, locking solutions, flushing intervals and techniques, and surveillance of catheter-associated complications. Data were analyzed descriptively at the institutional level. RESULTS: Forty-eight centers were included (63.2%). Heparin was used as a locking solution for Broviac/Hickman catheters in 56.3% and for ports in 52.1% of centers, whereas 0.9% saline was used in 41.7 and 43.8%, respectively. Broviac/Hickman catheters were predominantly flushed weekly (87.5%), while port flushing intervals varied. Push-pause flushing was used by 60.4% of centers. Almost all centers had a standard operating procedure (97.9%), but only 41.7% systematically monitored catheter-associated bloodstream infections and thrombosis. DISCUSSION: Compared with the 2013 German Society for Pediatric Oncology and Hematology survey, in which approximately 90% of centers used heparin locking, heparin is now used considerably less frequently. Substantial interinstitutional heterogeneity persists. CONCLUSION: These findings highlight the need for harmonized, evidence-based recommendations and standardized prospective surveillance of central venous access device-associated complications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers