科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of Reconstructive Microsurgery2026-04-09· Medicine

Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach

Tae Hyung Kim, Seohee Chae, Donggeon Kim, Taehyun Kim, Jin Geun Kwon, Changsik John Pak, Hak-Soo Suh, Joon Pio Hong

原始摘要(英文原文)· Original abstract
Abstract Supermicrosurgery involving vessels ≤0.3 mm remains among the most technically demanding procedures in reconstructive surgery. Robotic platforms have shown potential to enhance precision, but their feasibility at this extreme scale requires further validation. Apprentice surgeons (≤5 years' experience) performed rat femoral vessel (approximately 0.26–0.30 mm) anastomoses using both hand-sewn and robotic-assisted techniques across eight consecutive trials. Outcome measures included Structured Assessment of Robotic Microsurgical Skills (SARMS) scores, operative time, stitch count, and patency rate. Learning curves were assessed with cumulative summation (CUSUM) analysis, and anastomotic quality was evaluated using scanning electron microscopy (SEM). Robotic-assisted anastomosis reached proficiency earlier than hand-sewn repair (4th versus 6th trial). Although initial operative time was longer for robotic cases (1,772 ± 120 seconds versus 1,355 ± 187 seconds, p = 0.013), times equalized by the 5th trial and decreased by 42% by the 8th (1,026 ± 58 seconds versus 1,023 ± 73 seconds, p = 0.959). Stitch counts were higher in later robotic trials (4.2 ± 0.6 versus 3.5 ± 0.5, p = 0.015). Both groups achieved 100% patency by the 4th trial. CUSUM and SEM analyses confirmed a steeper learning curve and superior anastomotic precision with robotic assistance. Robotic-assisted supermicrosurgery enables earlier proficiency, enhanced precision, and reproducible anastomotic quality compared with hand-sewn techniques. Despite longer initial times, robotic performance rapidly improved, achieving equivalent efficiency with greater technical control. These findings confirm the technical feasibility of robotic supermicrosurgery at the 0.3 mm scale and support its potential role in microsurgical and lymphatic reconstruction training and clinical practice.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach — 科研速览 Science Skim