From the paper's conclusion- These findings confirm the technical feasibility of robotic supermicrosurgery at the 0.3 mm scale and support its potential role in microsurgical and lymphatic reconstruction training and clinical practice.
Abstract
Abstract Supermicrosurgery involving vessels ≤0.3 mm remains among the most technically demanding procedures in reconstructive surgery. Robotic platforms have shown potential to enhance precision, but their feasibility at this extreme scale requires further validation. Apprentice surgeons (≤5 years' experience) performed rat femoral vessel (approximately 0.26–0.30 mm) anastomoses using both hand-sewn and robotic-assisted techniques across eight consecutive trials. Outcome measures included Structured Assessment of Robotic Microsurgical Skills (SARMS) scores, operative time, stitch count, and patency rate. Learning curves were assessed with cumulative summation (CUSUM) analysis, and anastomotic quality was evaluated using scanning electron microscopy (SEM). Robotic-assisted anastomosis reached proficiency earlier than hand-sewn repair (4th versus 6th trial). Although initial operative time was longer for robotic cases (1,772 ± 120 seconds versus 1,355 ± 187 seconds, p = 0.013), times equalized by the 5th trial and decreased by 42% by the 8th (1,026 ± 58 seconds versus 1,023 ± 73 seconds, p = 0.959). Stitch counts were higher in later robotic trials (4.2 ± 0.6 versus 3.5 ± 0.5, p = 0.015). Both groups achieved 100% patency by the 4th trial. CUSUM and SEM analyses confirmed a steeper learning curve and superior anastomotic precision with robotic assistance. Robotic-assisted supermicrosurgery enables earlier proficiency, enhanced precision, and reproducible anastomotic quality compared with hand-sewn techniques. Despite longer initial times, robotic performance rapidly improved, achieving equivalent efficiency with greater technical control. These findings confirm the technical feasibility of robotic supermicrosurgery at the 0.3 mm scale and support its potential role in microsurgical and lymphatic reconstruction training and clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Learning Curve in Robotic-Assisted Microsurgery: A Systematic Review of Skill Acquisition.Journal of reconstructive microsurgery · 2026
- Robot-assisted (super) microsurgery: A randomized in vivo preclinical trial for microvascular anastomosis.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- Dedicated Robotic-Assisted Microsurgery Platforms in Plastic and Reconstructive Surgery: A Systematic Review.Microsurgery · 2026
- From Virtual Reality to High-Fidelity Silicone Models: A Pilot Pathway for Training Vascular Surgeons in Robotic Skills.Annals of vascular surgery · 2026
- Expanding the Role of Robot-assisted Microsurgery: Implementation, Challenges, and Outlook From a High-volume Tertiary Care Center.Plastic and reconstructive surgery. Global open · 2026
- A Novel Intraluminal Microtube Anastomosis System (IMAS) for Rapid Rat Microvascular Reconstruction: Development and Experimental Evaluation.Journal of clinical medicine · 2026