MATEC Web of Conferences

Performance evaluation of a polynomial regression based NUC for variable integration-time

Mathews Chirindo, Mirriam Molekoa

Key points

From the paper's conclusion
  • The results demonstrate that the PRM provides a practical and flexible correction framework for variable operating conditions while significantly reducing calibration storage requirements.

Abstract

Non-Uniformity Correction (NUC) is essential for improving infrared image quality but is challenged by increased calibration-factor storage demands and performance variations, particularly under variable integration times and operating temperatures. This paper investigates a temperature-adaptive Polynomial Regression Model (PRM) for NUC under variable integration-time conditions. The proposed method employs temperature-interpolated polynomial coefficients to estimate corrected pixel values across a continuous range of temperatures and integration times. The model is validated using real detector data and its performance is compared against two established NUC methods, namely two-point NUC (TPN) and a 2D calibration scheme. The proposed approach requires three times less memory than TPN while maintaining a competing residual non-uniformity (RNU) of less than 1% across the tested integration times. The results demonstrate that the PRM provides a practical and flexible correction framework for variable operating conditions while significantly reducing calibration storage requirements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers