Hydraulic Resistance of the Internal Shunt of a Double-Balloon Catheter for Percutaneous Hepatic Perfusion: An In Vitro Study
Jan Turra, Oliver Biecker, Osman Oecal, Maik Von der Forst, Max Dietrich, Philippe Grieshaber, Folker Wenzel, Jessica Hassel,
Key points
From the paper's conclusion- The results are limited to one catheter in a rigid-tube model.
Abstract
Background: Percutaneous hepatic perfusion (PHP) isolates the liver circulation with a double-balloon catheter whose internal shunt maintains venous return from the lower body during balloon occlusion of the inferior vena cava (IVC). Clinically, PHP is associated with hypotension and high catecholamine requirements. This in vitro study quantified the hydraulic resistance of the shunt. Methods: One 16 F double-balloon catheter was tested in a bench model (12.7 mm PVC tubing, open reservoir) using a blood analog (43% glycerol by mass) at 21.4–22.4°C. A centrifugal pump generated flows at 500–4000 RPM with uninflated and inflated balloons (4 mL NaCl); flow and pressure were recorded (n = 5 per step). Results: With uninflated balloons, flow reached 7.55 ± 0.05 L/min at a pressure gradient of 31.6 ± 0.5 mmHg (4000 RPM). After inflation, flow was restricted to the shunt lumen and reduced by 96.9% (500 RPM) to 93.3% (4000 RPM). The maximum shunt flow was 0.51 ± 0.01 L/min at 387 mmHg; at 10 mmHg it was approximately 0.02 L/min. The resistance (ΔP/flow) rose from 493 to 762 mmHg·min/L (p < 0.001). Flow was laminar (Reynolds number < 1800). Conclusion: In this bench model, the internal shunt was a severe hydraulic bottleneck that is unlikely to carry physiological venous return at low venous driving pressures. Occlusion time should be kept short with close hemodynamic monitoring, and shunt design optimization should be investigated. The results are limited to one catheter in a rigid-tube model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Asymmetric Sensitivity of Hepatic Venous Pressure Gradient to Portal and Sinusoidal Resistance: An In Vitro Experimental Study.Biosensors · 2026
- Venous dimension of shock: Integrating arterial inflow and venous back-pressure in hemodynamic assessment.World journal of critical care medicine · 2026
- Percutaneous Insertion of Hepatic Arterial Infusion Ports by Interventional Radiology for Colorectal Liver Metastases.Cancers · 2026
- Pressure behavior in a roller pump-driven low-flow VACC mock circuit with inactive de-airing pump: A descriptive bench characterization under reduced patient-side effective filling pressure conditions.PloS one · 2026
- Locoregional Therapy Pressure-Enabled Drug Delivery for Liver Cancers.Cancers · 2026
- Characterization of an adjustable partial portal vein ligation model reveals flow-dependent intimal and medial remodeling of the extrahepatic portal vein.Vascular pharmacology · 2026