Power Quality Enhancement in Reverse Osmosis Desalination Plants Through Active Harmonic Filtering
Cherki Lahlou, Moad El Kamili, Belaid Bouikhalene, Jamaa Bengourram, Hassan Latrache, Mustapha Mabrouki
Key points
From the paper's conclusion- Power quality degradation caused by harmonic distortion is a major challenge in reverse osmosis (RO) desalination plants equipped with high-power variable frequency drives (VFDs).
Abstract
Power quality degradation caused by harmonic distortion is a major challenge in reverse osmosis (RO) desalination plants equipped with high-power variable frequency drives (VFDs). Although previous studies have mainly focused on harmonic assessment, prediction, or simulation-based mitigation strategies, limited attention has been paid to the experimental validation of harmonic mitigation under real operating conditions in large-scale industrial facilities. This study proposes an integrated AI-guided engineering framework for evaluating the effectiveness of active harmonic filtering in the MAROC CENTRAL RO desalination plant, Morocco. Building upon a previously developed artificial intelligence (AI)-based harmonic diagnosis, the proposed approach supports the identification of critical operating conditions and the selection of an appropriate harmonic mitigation strategy. Harmonic measurements identified the operation of three RO trains as the most critical condition, with average Total Harmonic Distortion of Voltage (THDu) and Current (THDi) values of 7.8% and 54.3%, respectively. Based on a comparative evaluation of passive, hybrid, and active filtering technologies, a 480 A ENERSINE active harmonic filter was installed at the point of common coupling. Experimental results demonstrated a reduction in THDi from 51.36% to 9.68% (81.2%) and in THDu from 5.66% to 4.61% (18.5%), ensuring compliance with IEEE 519, IEC 61000, and EN 50160 standards. The proposed solution also reduced the RMS current and active power demand of the high-pressure pumps without affecting hydraulic operating conditions, thereby improving energy efficiency, equipment reliability, and maintenance performance. The proposed framework provides a practical and scalable methodology for harmonic mitigation and sustainable operation of large-scale industrial RO desalination plants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Reinforcement Learning-Assisted Universal Active Filter for Power Quality Enhancement in a SyRG-Based Standalone Renewable Energy System with Hybrid Energy StorageInternational Journal for Research in Applied Science and Engineering Technology · 2026
- Time-aware evaluation of metaheuristic-optimized support vector regression for permeate conductivity in hybrid nanofiltration–reverse osmosis desalinationJournal of King Saud University – Engineering Sciences · 2026
- Anomaly diagnosis in SWRO desalination plants using a physics-informed spatiotemporal graph attention network.Water research · 2026
- Techno-economic analysis of an integrated desalination-renewable-hydrogen system for zero-emission freshwater and electricity productionEnergy Conversion and Management · 2026
- Energy optimization of reverse osmosis desalination systems in arid regions: A case study in MoroccoDesalination and Water Treatment · 2026
- Renewable energy-driven desalination technologies: Energy performance, renewable coupling and sustainability challengesE3S Web of Conferences · 2026