Multiphysics thermo-optical investigation of the bolometric diagnostics
V. D’Agostino, E. Peluso, A. Belpane, I. Wyss, M. Gelfusa, S. Palomba, L. Gabellieri, A. Murari,
Key points
From the paper's conclusion- The design of bolometric cameras requires a multiphysics thermo-optical investigation, including thermal and mechanical stability and protection against stray radiation, to be considered together with optical factors such as pinhole geometry, lines of sight (LoS), and tomographic reconstruction accuracy.
Abstract
Bolometric diagnostics plays a crucial role in tokamaks, providing line-integrated measurements of plasma radiation and supporting energy balance and operation safety and control. Resistive bolometers, based on metallic absorbers and meander sensors integrated in a Wheatstone bridge, convert thermal variations into electrical signals proportional to the absorbed power. The design of bolometric cameras requires a multiphysics thermo-optical investigation, including thermal and mechanical stability and protection against stray radiation, to be considered together with optical factors such as pinhole geometry, lines of sight (LoS), and tomographic reconstruction accuracy. The presented case study is particularised for the Italian tokamak DTT (Divertor Tokamak Test), now under construction at the ENEA Research Centre in Frascati (Rome). A multiphysics approach is used to review and critically assess the main thermal and mechanical challenges associated with the design of bolometric diagnostics for next-generation tokamaks. First, a finite element analysis was carried out on the DTT bolometric system to assess the ability of the proposed layout to withstand thermo-structural loads. In parallel, a second analysis was carried out on a generic tokamak with a major radius larger than that of DTT, providing a conservative assessment of thermo-structural effects on the optical response and offering a methodology that can be directly transferred to the actual DTT geometry. The work is focused on identifying the key limitations, failure modes, and design trade-offs that must be addressed to ensure reliable and robust measurements under extreme operating conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Upgrade of the RADCAM diagnostic for the TCV tokamak with tangential bolometer sightlines.The Review of scientific instruments · 2026
- Design and development of plasma diagnostics to tackle the Divertor Tokamak Test research objectives (invited).The Review of scientific instruments · 2026
- A multi-pulse, multi-species laser blow-off system on DIII-D for impurity transport studies.The Review of scientific instruments · 2026
- Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operationNuclear Fusion · 2025
- Miniaturized fiber-optic bolometer with reduced thermal time constant exhibiting first-order thermal dynamics.The Review of scientific instruments · 2026
- Implementation of a tightly baffled long-legged divertor in TCVNuclear Fusion · 2026