Performance Evaluation of a Novel Automatic Shading Control System for High-Rise Buildings Using Simulation Techniques
Ernest Tsang, Shuyang Li, Kevin Kwok, Stephen Lam, Roger NG
Key points
From the paper's conclusion- The results indicate a strong relationship between indoor illuminance and daylight glare metrics, including the daylight glare index and daylight glare probability.
Abstract
Hong Kong is one of the world’s most densely built cities, where high-rise buildings are typically located in close proximity. In such environments, daylight availability is largely determined by visible sky conditions and solar position. Integrating daylight-linked lighting control (DLLC) with automatic shading control (ASC) adds further complexity to system performance. Conventional ASC strategies commonly rely on either exterior vertical illuminance or interior glare assessment based on high-dynamic-range (HDR) imaging, but both approaches have limitations. Systems using a single vertical illuminance threshold may trigger inappropriate shading operation; for example, when the sun is at a high altitude, vertical illuminance can remain high even though daylight penetration is limited. Conversely, image-based ASC systems cannot adequately reflect outdoor weather conditions once shading has been deployed. To address these limitations, this study proposes a novel ASC control algorithm. The results indicate a strong relationship between indoor illuminance and daylight glare metrics, including the daylight glare index and daylight glare probability. Using long-term weather data and exterior vertical illuminance, indoor glare levels were predicted to support the development of an improved control strategy. The relative importance of weather and control parameters was also identified. The daylighting and energy performance of the proposed ASC system were evaluated through simulation and compared with those of conventional ASC systems based on a single outdoor vertical illuminance threshold.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Using computer-vision AI for occupant-centric control of solar shadingE3S Web of Conferences · 2026
- Nighttime Lighting Effect on a University Residential BuildingBuildings · 2026
- Glare rating at different ages: the limits of the UGR method applied to a real case studyJournal of Physics: Conference Series · 2026
- Targeting integrated daylighting comfort in deep office by multi-objective optimization using partial vertical deployment of adaptive corrugated shadingsEnergy and Built Environment · 2026
- Assessing Impacts of Surrounding Building on Glare Risk Across Local Climate ZonesJAPAN ARCHITECTURAL REVIEW · 2026
- Challenges in Daytime Outdoor Glare Evaluation Within the Built Environment: A ReviewBuildings · 2026