Systematic ground-effect bias in heat transfer coefficient estimation
Justinas Smertinas, Matthias Van Hove, Thibault Péan, Peder Bacher, Henrik Madsen
Key points
From the paper's conclusion- The findings show that omitted physics can produce systematic, yet interpretable parameter bias, even when predictive performance is strong, underscoring the need for bias-aware model formulations in building energy performance assessment.
Abstract
Data-driven building energy models often represent the building envelope using a single effective heat transfer coefficient (HTC), implicitly assuming uniform boundary conditions. In practice, this assumption is violated because floors are thermally coupled to the ground, whose temperature differs systematically from outdoor air temperature. This work examines how omission of ground coupling introduces bias in HTC estimation. A time window-level expression for the ground-effect relative bias is derived for a simplified RC network representation and shown to depend on both the floor share of total envelope conductance and an accumulated ground-effect factor over the estimation window. The effect is then investigated using synthetic high-resolution data generated from detailed Modelica simulations of archetypal single-family houses, with 2R2C models identified on moving 21-day windows. Results show that the empirical relative bias scales systematically with floor heat-transfer share and that its seasonal variation is closely tracked by the derived ground-effect bias. At the same time, the mean bias across buildings remains close to zero, indicating cancellation between competing structural bias components. The findings show that omitted physics can produce systematic, yet interpretable parameter bias, even when predictive performance is strong, underscoring the need for bias-aware model formulations in building energy performance assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Data-driven moving-window Bayesian inference for transient CO2–temperature network models of buildingsJournal of Mathematics in Industry · 2026
- Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone BuildingarXiv · 2026
- A global base temperature dataset for residential building energy demand modellingEarth system science data · 2026
- From BIM and white-box models to grey-box models: Model identification and long-horizon prediction of building thermal dynamicsE3S Web of Conferences · 2026
- NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy ModelingarXiv · 2026
- Estimation of building energy demand characteristics using bayesian statistics and energy signature modelsEnergy and Buildings · 2026