E3S Web of Conferences

Energy and Exergy Analysis of a Transversely Corrugated Roughened Solar Absorber Integrated with a Flat Heat Pipe for a Sand-Based Thermal Energy Storage System under Charging and Discharging Conditions

Khridsadakhon Booddachan, Surachet Sichamnan, Yulong Ding, Yongliang Li, Jittimon Wongsa, Nipon Bhuwakietkumjohn, Sanjeeva Witharana, Thanya Parametthanuwat

Key points

From the paper's conclusion
  • These findings indicate that absorber-surface modification combined with flat heat pipe integration can improve the overall performance of solar thermal energy storage systems under low and intermittent irradiance conditions.

Abstract

This study experimentally investigated the overall system performance and exergy performance of a closed-loop solar thermal energy storage system integrating three solar absorber tube configurations: a triangular transversely corrugated roughened tube, a roughened tube, and a smooth tube. Each absorber was coupled with a flat heat pipe and a sand-based thermal storage unit under charging and discharging conditions. The objective was to enhance solar absorption, heat transport, and thermal energy storage performance. The results showed that the triangular transversely corrugated roughened tube provided superior heat transfer performance compared with the smooth and conventional roughened tubes. During charging, the system increased the thermal energy stored in sand by approximately 15 – 25%. During discharging, the stored heat was effectively recovered, with a maximum heat transfer rate of approximately 10 – 16 W and a higher outlet water temperature than those of the other configurations. The overall system performance ranged from 0.70 to 0.75, while the exergy ranged from 0.50 to 0.55, consistent with the characteristics of low-grade thermal energy storage systems. Although the exergy efficiency remained relatively low, the triangular transversely corrugated roughened tube consistently achieved the highest overall performance. These findings indicate that absorber-surface modification combined with flat heat pipe integration can improve the overall performance of solar thermal energy storage systems under low and intermittent irradiance conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.