Numerical assessment of groundwater-table effects on building-floor displacement under seismic surface waves

Akbarjon Abdunazarov, Sharafitdin Yuldashev, Muhammadbobir Boytemirov, Boburkhon Vakhobov, Jonibek Bozorov

Key points

From the paper's conclusion
  • This study evaluated the floor-by-floor displacement response of a multi-storey building subjected to Rayleigh-type excitation for groundwater levels of 20 m and 4 m below the ground surface.

Abstract

Groundwater-table depth alters the saturated and unsaturated zones of a soil profile and can influence seismic surface-wave transmission to building foundations. This study evaluated the floor-by-floor displacement response of a multi-storey building subjected to Rayleigh-type excitation for groundwater levels of 20 m and 4 m below the ground surface. A three-dimensional PLAXIS 3D soil-foundation-building model was developed using a 200 × 100 × 50 m domain, 44,836 tetrahedral elements, and a 24 × 24 m, 27 m high building with a 3 m basement. Drained linear-elastic loam and gravel layers, viscous absorbing boundaries, Newmark time integration, and a 10 Hz harmonic displacement applied for 5 s were used. The 4 m groundwater table reduced peak horizontal displacement at all monitoring levels. Basement displacement decreased from 2.59 to 2.11 mm, the first-floor response from 2.59 to 2.03 mm, and roof displacement from 1.28 to 1.02 mm, corresponding to reductions of 18.53%, 21.62%, and 20.31%, respectively. The average reduction was approximately 19-20%. These results show that groundwater conditions can significantly affect computed soil-structure interaction, although the findings remain specific to the adopted material model, excitation frequency, and boundary conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers