Evaluation of Barramundi ( Lates calcarifer ) Brain Extract as a Potential Thromboplastin Reagent for Prothrombin Time Testing
Putri Sari Uswatun Hasanah, S. N. Depamede, Nur Indah Julisaniah, Mohammad Rizki
Key points
From the paper's conclusion- This early proof-of-concept study evaluated barramundi brain extract (INO) in phosphate-buffered saline (PBS) as a candidate thromboplastin reagent for PT and compared it with the commercial Stago reagent in 20 citrated plasma samples.
Abstract
Prothrombin time (PT) testing relies on imported commercial thromboplastin reagents, so a local alternative source is needed. Barramundi ( Lates calcarifer ) is a leading mariculture commodity in the working area of the Lombok Marine Aquaculture Center, including West Nusa Tenggara, whereas its brain, which is presumed to be rich in tissue factor (TF) and phospholipids, remains little utilized. This early proof-of-concept study evaluated barramundi brain extract (INO) in phosphate-buffered saline (PBS) as a candidate thromboplastin reagent for PT and compared it with the commercial Stago reagent in 20 citrated plasma samples. The extract was prepared in two batches (A280-based nominal concentrations of 5.89 ± 0.40 and 8.95 ± 0.72 mg/mL). Batch 1 was used to screen the concentration range, whereas batch 2 was used to test patient samples. The working reagent contained 12.5 mM CaCl 2 added directly to the reagent to recalcify the citrated plasma, and was tested using the manual tilt-tube method. A nominal concentration of 0.63 mg/mL was designated as the provisional concentration, based on experimental screening conditions, because it was closest to Stago in both batches (sums of absolute differences of 1.00 and 1.10 seconds). Duplicate repeatability testing ( n = 2) on batch 2 gave coefficients of variation (CV) of 1.32% in normal plasma and 11.56% in abnormal plasma; the latter did not meet the predefined criterion (CV ≤ 5%), so all precision data are regarded as preliminary. In the 20 samples, the PT was 6.21 ± 1.27 seconds for INO and 5.83 ± 1.86 seconds for Stago ( p = 0.233; r = 0.68); the Bland-Altman bias was +0.38 seconds, with limits of agreement of -2.31 to +3.06 seconds. These p and r values do not demonstrate method equivalence or clinical acceptability. The extract showed thromboplastin-like clot-promoting activity, but the two reagents cannot yet be used interchangeably; clinical acceptability requires a predefined total error tolerance limit, International Sensitivity Index (ISI) / International Normalized Ratio (INR) calibration, and validation of shelf-life, inter-batch consistency, and performance on automated analyzers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of platelet rich plasma preparations by routine centrifuge versus two commercially available standardized centrifuges.Pakistan journal of medical sciences · 2026
- Comparative study of blood biochemistry in clinically healthy farmed barramundi ( Lates calcarifer ) and rainbow trout ( Oncorhynchus mykiss ) from freshwater recirculating aquaculture systemsAustralian Veterinary Journal · 2026
- Collaborative study for the calibration of replacement batches for the European Pharmacopoeia Heparin sodium Biological Reference Preparation.Pharmeuropa bio & scientific notes · 2026
- A human-cell recombinant prethrombin-2 platform producing thrombin with enhanced fibrinogen processing for in vitro applications.Thrombosis research · 2026
- A-249 Evaluation of three cartridge-based analyzers for viscoelastic testingClinical Chemistry · 2026
- In Vitro Anticoagulant Effects of Fucoidan-Rich Extracts from South African Brown Macroalgae.Molecules (Basel, Switzerland) · 2026