BIO Web of Conferences

Sensory Characteristics of Mushroom Rendang Thermally Sterilized Using a Low-Cost Pressure Cooker Sterilizer for Small-Scale Food Processing

Risa Meutia Fiana, Novelina, Harmadi, Azzikral Hakim, Rendri Yaswan, Novizar, Daimon Syukri

Key points

From the paper's conclusion
  • These findings demonstrate that pressure cooker sterilizers, when combined with temperature monitoring and Fo validation, can be utilized as a practical and affordable thermal processing alternative for SMEs producing safe and shelf-stable mushroom rendang.

Abstract

Small and medium enterprises (SMEs) often face challenges in producing shelf-stable ready-to-eat foods due to limited access to industrial retort systems and validated thermal processing methods. This study aimed to determine the optimum sterilization time for mushroom rendang processed using a pressure cooker sterilizer based on the Fo value and product quality attributes. Mushroom rendang was sterilized for 50, 70, and 90 min after venting. Product temperature at the cold point was continuously monitored using a temperature data logger, and the accumulated lethality (Fo) was calculated using a reference temperature of 121.1°C and a z-value of 10°C. Sensory evaluation and moisture content analysis were performed to assess the impact of sterilization on product quality.The temperature profile showed that the accumulated lethality increased with increasing processing time. The treatment sterilized for 70 min achieved an Fo value exceeding 3 min, indicating adequate thermal processing for shelf-stable products. Sensory evaluation revealed that mushroom rendang remained acceptable to panelists after sterilization, with no significant differences (p > 0.05) between products before and after processing. Likewise, moisture content was not significantly affected by sterilization time. Although the 90-min treatment produced a higher Fo value, it did not provide additional quality benefits compared with the 70-min treatment.Based on thermal process adequacy, sensory acceptance, and moisture retention, sterilization for 70 min after venting was identified as the optimum condition. These findings demonstrate that pressure cooker sterilizers, when combined with temperature monitoring and Fo validation, can be utilized as a practical and affordable thermal processing alternative for SMEs producing safe and shelf-stable mushroom rendang.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers