Astronomy & Astrophysics

X-ray polarimetry of a magnetar in the aftermath of an anti-glitch. Revisiting 1E 2259+586 with IXPE

Ruth M. E. Kelly, Roberto Taverna, Roberto Turolla, Lorenzo Marra, Swati Ravi, Jeremy Heyl, Silvia Zane, Mingyu Ge,

Key points

From the paper's conclusion
  • We present an analysis of the recent observation of that spans ∼ 11 days, from late April to early May 2026, after its anti-glitch event in 2025.

Abstract

Magnetars have been known to display timing anomalies such as glitches and anti-glitches. In particular, the anomalous X-ray pulsar whose properties in the X-ray band were recently investigated through a joint observation campaign, has been observed to have multiple glitches and three anti-glitches, the most recent occurring in May 2025. Although the X-ray emission is currently decaying, the flux, which roughly doubled at the onset of the anti-glitch, had not yet returned to its original level at the time of the observation, and the pulse profile has also shown significant evolution. We present an analysis of the recent observation of that spans ∼ 11 days, from late April to early May 2026, after its anti-glitch event in 2025. We compare the post-anti-glitch polarisation results with those obtained from the previous observation in 2023. This provides an unprecedented opportunity to monitor the spectro-polarimetric evolution of a magnetar in the wake of a hallmark event such as an anti-glitch. A dedicated 400, and Director’s Discretionary Time (DDT) observation was approved to track possible changes in the degree and angle of polarisation with respect to the pre-anti-glitch campaign. Spectral and polarimetric properties were jointly modelled within the xspec ixpeobssim suites, and the analysis was further expanded using a maximum-likelihood technique. No significant detection was found in the phase-averaged and energy-integrated spectrum of this observation. However, despite the significantly shorter exposure, polarisation was clearly detected in the phase-resolved spectrum and the degree of polarisation was found to have a higher best-fitting value, though still statistically consistent, than the previous measurement from 2023, reaching a level gtrsim30% in correspondence to the pulse profile minimum. In spite of some slight differences between the two observations, the polarisation trends remain largely consistent and indicate that the source has mostly returned to its pre-event state.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

X-ray polarimetry of a magnetar in the aftermath of an anti-glitch. Revisiting 1E 2259+586 with IXPE — Science Skim