Comparison of hybrid and standard reconstruction methods on IXPE astrophysical data
R. Ferrazzoli, N. Cibrario, S. Silvestri, M. Negro, P. Soffitta, S. Chakraborty, S. Pagliarella, S. R. Ehlert
Key points
From the paper's conclusion- We present the first comparison of hybrid and standard reconstruction methods on IXPE data of astrophysical point sources, with the aim of quantifying the improvement in polarimetric sensitivity as a function of energy.
Abstract
A hybrid reconstruction algorithm combines a convolutional neural network (CNN) with standard moment analysis to improve the reconstruction of photoelectron tracks in the gas pixel detectors (GPDs) on board the Imaging X-ray Polarimetry Explorer (IXPE). The method has been validated on laboratory calibration data, but its performance on astrophysical sources with known polarimetric properties has not yet been systematically characterized. We present the first comparison of hybrid and standard reconstruction methods on IXPE data of astrophysical point sources, with the aim of quantifying the improvement in polarimetric sensitivity as a function of energy. We analyzed two IXPE observations selected to probe complementary regimes: Her X-1, a bright and highly polarized accreting X-ray pulsar used as a quantitative benchmark, and the transient neutron star low-mass X-ray binary XTE J1701-461 in its soft state, a bright source with no detectable polarization used to measure residual systematic effects. For each source, we compared the normalized Stokes parameters, the degree of polarization (PD) and angle (PA), and the detection significance derived from the level 2 event files produced by both pipelines. For Her X-1, the hybrid method yields a consistently higher detection significance at all energies, with a statistically significant improvement above ∼2.83 keV. The significance ratio, R = σ_ /σ_ , deviates from unity by up to 9.3σ in the 2.83-4.00 keV bin, rising to R = 1.18 ± 0.03 at 5.66-8.00 keV at 6.2σ. For XTE J1701-461, both methods yield polarization degrees consistent with zero and significance ratios consistent with unity. Through a Fourier analysis, we identify some modes (m = 3, m = 6, m = 12, and m = 15) with power excesses in the hybrid angle distributions at low energies, which are significant at $>7σ$ relative to the standard method, while at 5-8 keV all modes are consistent with the expected noise level for both methods: these modes are amplified by CNN but do not propagate to the Stokes parameters. hyb std The hybrid method provides a measurable and statistically significant improvement in the polarimetric sensitivity for bright point sources that is fully consistent with the predictions from laboratory calibrations and equivalent to a sim20% increase in effective area without the additional cost of observation time. The hexagonal-grid modes are a geometric artifact of the GPD pixel structure and have no effect on polarimetric results since the additional modes are orthogonal to the polarization modes. The improvement is robustly detected for the bright source examined here (σ_ std For the unpolarized source in our sample (σ_ std the central significance increase is consistent with the same trend, but is not individually resolved at the available statistics. These findings confirm the readiness of the hybrid method for systematic application to IXPE astrophysical data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In-orbit anomaly and recovery of IXPE detector 2arXiv · 2026
- On the potential of widening the band of X-ray polarimetryarXiv · 2026
- Structured generalized sliced Wasserstein distance for keV X-ray polarization analysis with gas pixel detectorThe European Physical Journal C · 2026
- Deconvolved IXPE Polarization Maps of the Crab Nebula in a Maximum-a-Posteriori FrameworkarXiv · 2026
- X-Ray Polarization and Spectral Variations in an Extreme High-synchrotron-peaked Blazar 1ES 1101–232The Astrophysical Journal · 2026
- Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localizationarXiv · 2026