Journal of materials chemistry. B

Construction of bilayered multifunctional hydrogels: an enzyme-free anti-interference platform for serum creatinine detection.

Guangwei Li, Kexin Wang, Dongliang Zhang, Xinzhu Wang, Haidong He, Yu Chen

Key Laboratory for Advanced Materials, School of Chemistry and Molecular Engineering, East China University of Science and Technology, 130 Meilong Road, Shanghai 200237, China. 3148704620@qq.com. · Department of Center Laboratory, Punan Branch of Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200125, China. 13847664896@163.com.

Key points

From the paper's conclusion
  • This sensing platform demonstrates exceptional anti-interference ability against common coexisting substances in serum, and its test results are in excellent agreement with hospital clinical measurements, fully validating its application reliability in complex real biological matrices.

Abstract

This enzyme-free anti-interference strategy for serum creatinine detection operates independently of biological enzyme reagents such as creatininase. It enables accurate quantification of serum creatinine via materials engineering and electrochemical technologies, while effectively eliminating a wide range of interfering factors. This detection scheme addresses a critical limitation of traditional enzymatic methods, namely their high susceptibility to interference from coexisting substances including IgM proteins, bilirubin and catecholamines. In the present work, a highly selective enzyme-free bilayer multifunctional hydrogel was developed for rapid creatinine detection. The upper PDADMAC/PVA hydrogel serves as a purification layer, which can efficiently remove or suppress the interference from coexisting biomolecules in blood through electrostatic adsorption. The underlying functional layer is constructed with a BPQDs-(Ag/PA)/PVA hydrogel serving as the electroactive recognition element. Leveraging the multi-component synergistic effect among black phosphorus quantum dots, silver nanoparticles and picric acid, cascaded amplification of the electrochemical response signal is achieved after the Jaffé reaction. The as-fabricated sensor exhibits an optimal linear relationship within 0-200 µM, with a low limit of detection down to 1.599 µM. Through 10-fold pre-dilution of serum samples and subsequent correction with the dilution factor, the indirect quantitative range for creatinine is successfully expanded to 2000 µM. This sensing platform demonstrates exceptional anti-interference ability against common coexisting substances in serum, and its test results are in excellent agreement with hospital clinical measurements, fully validating its application reliability in complex real biological matrices. Follow-up research will further break through the pre-treatment limitation to realize direct label-free detection of undiluted original serum specimens.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers