Soft matter

Control and synchronization of capillary flows in stepped microchannels.

H Desu, N S Satpathi, L Malik, A K Sen

Micro Nano Bio Fluidics Unit, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai - 600036, Tamil Nadu, India. ashis@iitm.ac.in.

Key points

From the paper's conclusion
  • These results establish a simple, geometry-mediated mechanism for passive control and synchronization of capillary flows, expanding the design space for microfluidic systems.

Abstract

Capillary-driven transport offers a simple, self-sustained alternative to externally pumped microfluidic systems, yet achieving precise control of such flows remains challenging. We experimentally and theoretically investigate capillary flow in rectangular microchannels when a liquid meniscus encounters a geometric step with varying channel width and height. Depending on the contact angle and step dimensions, the meniscus either pins or advances, defining distinct flow and no-flow regimes. Introducing a lateral offset between channel sidewalls provides an additional geometric control that enables reversible switching from a pinned to a flowing state, even for liquids with relatively high contact angles. We rationalize these transitions using numerical simulations and an energy-based scaling model that captures the balance between surface tension and Laplace pressure at the step. Finally, we demonstrate synchronization of capillary fronts in parallel microchannels by combining stepped and offset geometries. These results establish a simple, geometry-mediated mechanism for passive control and synchronization of capillary flows, expanding the design space for microfluidic systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers