A viscometer for shear-thinning power-law liquids using a measure of smear length.
Diya K Aravind, Mahrukh A Mir, Tagam Komut, Mahesh S Tirumkudulu
Department of Chemical Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076, India. mahesh@che.iitb.ac.in.
Key points
From the paper's conclusion- Here we extend it to shear-thinning power-law liquids, whose viscosity μ = Kn-1 depends on the shear rate through the consistency index K and the flow index n.
Abstract
A smear device measures the viscosity of a Newtonian liquid from the length of the smear left when a droplet is dragged across a glass slide by an angled blade, using the Landau-Levich film law. Here we extend it to shear-thinning power-law liquids, whose viscosity μ = Kn-1 depends on the shear rate through the consistency index K and the flow index n. A quasi-steady drainage model gives the smear length xf as the initial cross-sectional area of the liquid wedge trapped between the blade and slide, divided by the initial film thickness and multiplied by a drainage factor 2(2n + 1)/(4n - 1); it therefore varies with the smear speed U as xf ∝ U-2n/(2n+1), so the slope of ln xf against ln U returns n and the intercept returns K. The factor diverges at n = 1/4, below which a strongly shear-thinning droplet is never exhausted and no finite smear length exists. The film law is calibrated by 298 level-set simulations, of which the 175 in the thin-film window 0.5 ≤ n ≤ 0.9, K ≤ 10 Pas fix a device-specific prefactor g(n) that reproduces the simulated thickness to 3.6% and the speed exponent to ±0.11. Experiments on xanthan gum solutions whose rheometer index nrheo spans 0.67 to 0.26 recover that index within |n - nrheo| ≤ 0.23, and within 0.02 for the two intermediate concentrations. The consistency index is not recovered quantitatively, because the smear probes film shear rates of 5 × 103 - 2 × 104 s-1, up to a decade above the rheometer window. The device is an ultra-low-volume probe of the flow index over 1/4 < n ≤ 1.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A microfluidic vacuum-pressure-driven device for liquid viscosity measurementScientific Reports · 2026
- Solute pulse compression and spreading in power-law fluid flow through a semipermeable tubearXiv · 2026
- Linking Flow-Derived Local Slip Lengths to Force-Derived Effective Slip Lengths in Nanogaps.Langmuir : the ACS journal of surfaces and colloids · 2026
- Comparative Evaluation of Spreadability Measurement Methods for Topical Semisolid Formulations/A Scoping ReviewGels · 2025
- Practical Pendulum Viscometer Design for a Wide Measurement Range and High AccuracyMeasurement Science and Technology · 2026
- Liquid imbibition in paper pathways: Rheology–analyte coupling insightsPhysics of Fluids · 2026