π-Bridge engineering of NIR-II fluorophore nanoparticles for high-contrast bioimaging and image-guided surgery.
Weigeng Huang, Danmin Lin, Jun Zhu, Jiayi Chen, Shilin Chen, Hongxuan Liang, Dingyuan Yan, Dong Wang,
Center for AIE Research, Shenzhen Key Laboratory of Polymer Science and Technology, Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University Shenzhen 518060 China. · Guangdong Basic Research Center of Excellence for Aggregate Science, School of Science and Engineering, The Chinese University of Hong Kong Shenzhen (CUHK-Shenzhen) Guangdong 518172 China.
Key points
From the paper's conclusion- In subcutaneous breast cancer and orthotopic colorectal tumor models, TPE-HEXOT-DPTQ nanoparticles not only achieved high-contrast tumor imaging but also enabled precise surgical resection of malignant tissues.
Abstract
Early and accurate diagnosis is essential to timely clinical intervention. Compared with conventional imaging modalities such as magnetic resonance imaging and computed tomography, which remain subject to high cost, inadequate resolution, or ionizing radiation, near-infrared (NIR) fluorescence imaging provides high sensitivity, excellent spatial resolution, and minimal invasiveness. Nevertheless, the development of highly bright NIR fluorophores remains challenging because simultaneous optimization of the molar absorption coefficient (ε) and quantum yield (Φ PL) is difficult to achieve. Here, TPE-HEXOT-DPTQ is rationally designed through π-bridge engineering to balance molecular planarity and distortion. The concurrent optimization of ε and Φ PL endowed TPE-HEXOT-DPTQ nanoparticles with the highest fluorescence brightness, together with exceptional colloidal stability, photostability, and biocompatibility. In vivo NIR-II fluorescence imaging demonstrated remarkable tissue penetration, high spatial resolution, and superior signal-to-background ratios, enabling clear visualization of intricate vascular architectures, including cerebral and auricular vasculature. In subcutaneous breast cancer and orthotopic colorectal tumor models, TPE-HEXOT-DPTQ nanoparticles not only achieved high-contrast tumor imaging but also enabled precise surgical resection of malignant tissues. This work establishes a rational molecular design strategy for high-performance NIR-II fluorophores and highlights their considerable promise for bioimaging and imaging-guided surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrabright NIR‐II Nanoparticles for High‐Resolution In Vivo Imaging: From Systemic Vasculature Visualization to Pathological Microenvironment MonitoringAdvanced Materials · 2025
- Ultrabright NIR-II Nanoprobes for Ex Vivo Bioimaging: Protein Nanoengineering Meets Molecular EngineeringACS Nanoscience Au · 2025
- Asymmetric N,O-Centered Stable Diradical Nanoparticles for NIR-II Fluorescence Imaging-Guided Photothermal Tumor Therapy.Bioconjugate chemistry · 2026
- Ultrabright NIR-II fluorophores enabled by noncovalent conformational locking for in vivo inflammation imaging.Science advances · 2026
- Bright, Robust and Readily Accessible Fluorophore Family for NIR-II BioimagingJournal of the American Chemical Society · 2025
- Recent advances in NIR-II fluorescence imaging for biomedical applicationsAdvanced Interventional Materials · 2026