SERS-LFIA technology based on Au@Ag nanospheres for simultaneous detection of carbapenemases KPC and NDM.
Xueli Zhang, Qian Shi, HeFei Zha, Chunyan Liu, Mengjie Liang, Xin Zhang
Department of Medical Laboratory, Hospital of Xinjiang Production and Construction Corps, The Second Affiliated Hospital of Shihezi University School of Medicine Urumqi Xinjiang 830002 China xjzhangxin108@126.com.
Key points
From the paper's conclusion- We aimed to develop a surface-enhanced Raman scattering (SERS)-lateral flow immunoassay (LFIA) combined detection method for Klebsiella pneumoniae carbapenemase (KPC)- and New Delhi metallo-β-lactamase (NDM)-type carbapenemases based on SERS integrated with LFIA.
Abstract
We aimed to develop a surface-enhanced Raman scattering (SERS)-lateral flow immunoassay (LFIA) combined detection method for Klebsiella pneumoniae carbapenemase (KPC)- and New Delhi metallo-β-lactamase (NDM)-type carbapenemases based on SERS integrated with LFIA. Two Au@Ag core-shell nanomaterials with characteristic Raman peaks (1629 and 1078 cm-1) were used as SERS substrates, conjugated with KPC/NDM monoclonal antibodies to prepare SERS nanotags, and paired capture antibodies were coated on the T-line. After optimising antibody pairing and concentrations, a double-antibody sandwich SERS-LFIA was constructed. T-line Raman signals were measured via spectrometer. The assay was evaluated for sensitivity, specificity, reproducibility, and hook effect, with cut-off values established. Method comparison against polymerase chain reaction (PCR) and commercial colloidal gold kits was performed to assess diagnostic performance. A SERS-LFIA method for the specific detection of KPC and NDM was established, with a visual detection sensitivity of 5 ng mL-1 for both enzymes. Using the Raman spectrometer, the detection sensitivity improved to 0.2 ng mL-1 for KPC and 1 ng mL-1 for NDM. The critical concentration for the hook effect was 125 ng mL-1. The coefficients of variation for repeatability testing at low, medium, and high antigen concentrations were all less than 15%. The cut-off values for KPC and NDM were determined to be 846 and 784, respectively. Using PCR results as the gold standard, the diagnostic sensitivity and specificity of this method were both 100%, demonstrating a 100% agreement rate with commercial colloidal gold detection kits. The SERS-LFIA detection system may provide technical support for rapid identification of carbapenemase types.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasensitive detection of Pb2+ using a lateral flow immunoassay based on surface-enhanced Raman spectroscopy.Analytical methods : advancing methods and applications · 2026
- Dual-mode colorimetric-SERS biosensor for endotoxin detection based on core-shell CS@Cu, Fe-CDs-coated Ag@Au NPs.Mikrochimica acta · 2026
- Hollow AuAgPt@Ag nanoframes with independent modular functional regions for in situ SERS monitoring of 4-NTP catalytic reactions.Journal of colloid and interface science · 2026
- Complex Core-Satellite Nanoparticles with Trench-Structured Shells and Cavities for Highly Sensitive SERS-Based Lateral Flow Assays.Journal of the American Chemical Society · 2026
- Nanozyme-SERS cascade immunoassay: From in-situ generation to signal enhancement of diffusible reporters in hotspots of Ag-rich nanoshell monolayers.Biosensors & bioelectronics · 2026
- Sensitive SERS detection of antibiotics using Ag-coated nanostructures fabricated by femtosecond laser cross-scanning.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026