Reusable UV-crosslinked MIL-101(Fe)@CQD/polymer nanocomposite films for fluorescence detection of As(iii) in water.
Yunus Emre Toprak, Soner Çubuk, Memet Vezir Kahraman
Department of Chemistry, Faculty of Science, Marmara University 34722 Istanbul Türkiye mvezir@marmara.edu.tr.
Key points
From the paper's conclusion- The combined MIL-101(Fe), CQD, and UV-curable polymer platform therefore provides an easy-to-handle and reusable solid-state format for trace As(iii) determination in aqueous samples.
Abstract
The sensitive determination of trace As(iii) in environmental waters remains challenging, despite the availability of sophisticated instrumental techniques. Herein, a free-standing solid-state fluorescence sensing film was fabricated by immobilizing a MIL-101(Fe)@CQDs composite within a UV-curable polymer matrix. Structural, morphological, optical, and surface analyses using FTIR, XRD, UV-Vis spectroscopy, BET, SEM/STEM, DLS, and XPS supported the formation of the composite and its incorporation into the polymer network. The synthesized CQDs exhibited a photoluminescence quantum yield of 19.2 ± 3.2% (n = 3). Quantitative determination was based on the fluorescence-intensity difference (ΔI = I 0 - I). The calibration response was linear over 4.44 × 10-9-6.67 × 10-8 mol L-1 (R 2 = 0.9919), with an LOD of 1.49 × 10-9 mol L-1 and a calculated LOQ of 4.97 × 10-9 mol L-1. The method showed high tolerance toward the tested potentially interfering species, including As(v), Sb(iii), Sb(v), carbonate, bicarbonate, phosphate, and common metal ions. Practical applicability was evaluated using environmental water samples and certified reference materials for arsenic, yielding recoveries of 101.3-104.6% with relative standard deviations below 5%. Results for environmental water samples were consistent with direct HG-AAS performed without a separate As(v)-to-As(iii) pre-reduction step; this comparison was used as supporting evidence of analytical consistency rather than as proof of exclusive As(iii) detection. The same sensing film was reused over 150 measurement/regeneration cycles, with a 1.4% difference between the first and final responses. The combined MIL-101(Fe), CQD, and UV-curable polymer platform therefore provides an easy-to-handle and reusable solid-state format for trace As(iii) determination in aqueous samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensitive determination of arsenic in water using fluorescent CdS nanostructures.The Analyst · 2026
- A ratiometric fluorescence sensor based on HFeO-modified NH2-MIL-101(Fe) and Ru-embedded for supersensitive and visual detection of As(V) in water.Mikrochimica acta · 2026
- Fluorescence spectroscopy of gum arabic-derived carbon quantum dots: a green nanosensor for dantrolene determination via the inner filter effect.Analytical methods : advancing methods and applications · 2026
- A novel near-infrared fluorescence switching sensor based on polyamide derived carbon quantum dots for sequential detections of perfluorobutane sulfonic acid and Fe3⁺ ionsDiscover Materials · 2026
- Selective Laser Sintering of a Chitosan/MOF Composite: 3D-Printed Adsorbent for ArsenicACS Omega · 2025
- Stable nitrogen-doped carbon quantum dots with pH-controlled fluorescence response for Fe3+ detectionScientific Reports · 2026