RSC advances

Analytical quality-by-design-assisted RP-HPLC method for simultaneous determination of cinnamaldehyde and chrysin in a lipid-based delivery system and its greenness assessment.

Mohammed Arfath M I, Sushmitha, Verginia Stefhney Pinto, Amitha Shetty, Akhilesh Dubey, Namdev Dhas, Sri Renukadevi Balusamy, Manohar Mahadev

Nitte (Deemed to be University), NGSM Institute of Pharmaceutical Sciences (NGSMIPS), Department of Pharmaceutics Mangalore India manohar.m@nitte.edu.in. · Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education Manipal India.

Key points

From the paper's conclusion
  • An analytical quality-by-design (AQbD)-assisted reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous determination of cinnamaldehyde (CN) and chrysin (CR) in a lipid-based delivery system.

Abstract

An analytical quality-by-design (AQbD)-assisted reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous determination of cinnamaldehyde (CN) and chrysin (CR) in a lipid-based delivery system. The CN : CR ratio was initially selected based on glucose utilisation studies in insulin-resistant HepG2 cells and Chou-Talalay combination index analysis, which identified a 1 : 1 ratio as most favourable. Chromatographic conditions were systematically optimised using a central composite design (CCD), with wavelength, aqueous-phase composition, pH, flow rate, and column temperature as critical method parameters. The optimised method employed methanol:acetonitrile : 0.1% orthophosphoric acid (40 : 40 : 20, v/v/v; pH 3.0; flow rate 0.8 mL min-1; column temperature of 23 °C) and achieved baseline separation of CN and CR, with retention times of 5.602 and 7.683 min, respectively, and a resolution of 5.363. The method demonstrated satisfactory linearity, accuracy, precision, and sensitivity over the investigated concentration range and was successfully applied to quantify CN and CR in the optimised self-nanoemulsifying drug delivery system (SNEDDS), as well as in dissolution and in vitro lipolysis studies. The optimised SNEDDS exhibited a droplet size of 57.49 nm, a zeta potential of -21.6 mV, 97.1% transmittance, and an emulsification time of 4.26 s. At 240 min, the SNEDDS showed 61.77% CN and 90.91% CR release, compared with 37.42% and 68.71%, respectively, for the pure drugs. The environmental profile of the developed method was evaluated using AGREE and ComplexMoGAPI, yielding scores of 0.65 and 81. The developed AQbD-assisted RP-HPLC method provides a reliable analytical approach for the simultaneous quantification of CN and CR in a complex lipid-based formulation and for evaluating its performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers