RSC advances

A reversible N-acylhydrazone-based turn-on fluorescent probe for ultrasensitive detection of fluoride and cyanide in water, food, and oral-care products.

Hemanth, Hosakere D Revanasiddappa, M Jyothi Priya, Prema M, B Jayalakshmi, Berfin Sağir, Omer Kaygili, Niyazi Bulut,

Department of Studies in Chemistry, University of Mysore Manasagangotri Mysuru - 570 006 Karnataka India revanasiddappa1066@gmail.com. · Department of Botany, Maharani's Science College for Women Mysuru - 570 005 Karnataka India.

Key points

From the paper's conclusion
  • A DHBH-coated cotton-bud test kit was designed for quick fluorescent detection of F- and CN-.

Abstract

A new N-acylhydrazone N'-(6-bromo-2-hydroxy-3-methoxybenzylidene)-2,4-dihydroxybenzohydrazide (DHBH), was designed as a turn-on fluorescent sensor for the specific identification of F- and CN- ions. FTIR, 1H NMR, 13C NMR, and LCMS analyzes were used to determine the molecular structure of DHBH. In its free state, DHBH showed modest fluorescence; however, the addition of F- or CN- resulted in a strong fluorescence amplification, which was ascribed to ion-induced modifications in the intramolecular hydrogen-bonding environment. In line with the improved DFT results, Job's plot technique determined a 1 : 1 binding stoichiometry for both anions. Further evidence of DHBH's preferred sensitivity to F- and CN- came from competitive-ion tests. Binding constants of 4.52 × 102 M-1 for F- and 7.79 × 102 M-1 for CN- were obtained from the related Benesi-Hildebrand analyses. DHBH showed low detection limits of 38.9 nM for F- and 38.6 nM for CN-, both significantly below the relevant WHO recommendation values for drinking water. Trifluoroacetic acid (TFA) treatment of the DHBH-anion complexes confirmed the reversible sensing behaviour. F- was found in commercial toothpaste and mouthwash samples, demonstrating practical applicability, whereas CN- was found in apple seeds (Malus domestica), potatoes (Solanum tuberosum), and cassava (Manihot esculenta). HOMO-LUMO analyzes and solvent-dependent DFT computations shed more light on the electronic alterations connected to anion recognition. A DHBH-coated cotton-bud test kit was designed for quick fluorescent detection of F- and CN-. The fluorescence amplification of the test kit under UV exposure was investigated by RGB imaging using smartphone-based application and the R/G ratio served as a simple semi-quantitative indicator of the concentration of the analyte.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers