A chemometrically validated discriminative sensing strategy combining biomolecular specificity with data-driven classification of Aβ1-40 fibrils.
Mrinalini Singh, Priyam Ghosh, Srinivas Rati, Bithiah Grace Jaganathan, Parameswar Krishnan Iyer
Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati-781039, Assam, India. pki@iitg.ac.in. · Jyoti and Bhupat Mehta School of Health Science and Technology, Indian Institute of Technology Guwahati, Guwahati-781039, Assam, India.
Key points
From the paper's conclusion- This work establishes a chemometrically validated sensing strategy that combines molecular specificity with data-driven classification via both absorbance and emission spectroscopy, offering a scalable approach for the selective detection of Aβ1-40 fibrils relevant to Alzheimer's disease (AD) diagnostics.
Abstract
Achieving selective and sensitive early detection of amyloid-β (Aβ1-40) fibrils, the hallmark of neurodegenerative disease, in the presence of monomers and abundant serum proteins remains a long-standing major challenge for detecting the disease at its preclinical stage. Here, we report a rationally designed fluorescent probe that exhibits a pronounced 585 nm emission enhancement, enabling rapid and selective identification of Aβ1-40 fibrils with minimal background interference, highlighting its potential for detecting Aβ1-40 fibrils. The probe shows negligible response toward monomers and common proteins, including human serum albumin (HSA), bovine serum albumin (BSA), and lysozyme, demonstrating high selectivity to Aβ1-40 fibrils. Mechanistic studies using NMR (Nuclear Magnetic Resonance), FTIR (Fourier-Transform Infrared), CD (Circular Dichroism), and UV-visible spectroscopy reveal that the sensing response arises from specific probe-fibril interactions, including site-dependent binding and π-π stacking with β-sheet structures. CD and FTIR analyses confirm fibril formation and structural integrity, while NMR provides molecular-level evidence of binding-induced perturbations. Chemometric analysis, including principal component analysis (PCA), hierarchical cluster analysis (HCA), k-nearest neighbours (kNN), and partial least squares discriminant analysis (PLS-DA), enables clear classification of fibrils, monomers, and protein interferents with an accuracy of 88.8% and 90%, using fluorescence and absorbance, respectively, validating the potential of the sensing platform. This work establishes a chemometrically validated sensing strategy that combines molecular specificity with data-driven classification via both absorbance and emission spectroscopy, offering a scalable approach for the selective detection of Aβ1-40 fibrils relevant to Alzheimer's disease (AD) diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Discriminating Monomers and Fibrils of Amyloid-β1-42 With Site-Ordered Peptide-QMFluors.Angewandte Chemie (International ed. in English) · 2026
- Highly sensitive and specific high-throughput detection of Aβ42 in clinical specimens using a G-quadruplex-structured fluorescent aptamer analysis platform.Talanta · 2026
- NanoGold-enhanced biomimetic sensor for Tau-441 protein detection in serum for Alzheimer's disease diagnosisBioelectrochemistry · 2026
- 1H, 13C, and 15N chemical shift assignments of monomorphic Aβ1-40 at 100 kHz MAS in a diamond rotor.Research square · 2026
- Molecular Binding in Supramolecular Fibrillar Biomolecules.Biophysical journal · 2026
- A signal-locked clamped hybridization chain reaction nanoamplifier for rapid and highly sensitive analysis of Aβ42.Talanta · 2026