Plasmonic cysteine nanoparticles for studying fluctuations in 5-hydroxytryptamine levels of spiked human serum.
Ridhima Chadha, Abhishek Das, Bhagyashree Chalke, Nandita Maiti
Radiation & Photochemistry Division, Bhabha Atomic Research Centre, Mumbai 400085, India. nanditab@barc.gov.in. · Department of Condensed Matter Physics and Material Sciences, Tata Institute of Fundamental Research, Mumbai 400005, India.
Key points
From the paper's conclusion- This study reports the fabrication of a plasmonic cysteine nanosubstrate (cys-AuNS) for studying fluctuations in the levels of the neurotransmitter 5-hydroxytryptamine (5HT) in aqueous media and in spiked human serum by surface-enhanced Raman scattering (SERS).
Abstract
This study reports the fabrication of a plasmonic cysteine nanosubstrate (cys-AuNS) for studying fluctuations in the levels of the neurotransmitter 5-hydroxytryptamine (5HT) in aqueous media and in spiked human serum by surface-enhanced Raman scattering (SERS). The sensing strategy is based on hot spot generation resulting in amplification of the SERS intensity. This is primarily due to the interaction of cys-AuNS with 5HT in solution and in spiked human serum. The enhancement in SERS intensities was probed by recording the time-dependent SERS measurements using 632 nm excitation. The results suggest an initial increase in the intensity, followed by signal saturation within ∼600 s. The evolution in SERS signal was found to be in synchronization with the time-dependent hot spot generation and aggregation of cys-AuNS, providing mechanistic insight into the plasmonic enhancement. Owing to the biocompatibility of cys-AuNS, it holds potential for both in vitro and in vivo SERS based monitoring of fluctuations in 5HT levels of human serum. The procedure to monitor fluctuations in 5HT levels involves an ultrafiltration assisted approach for effective extraction of 5HT from the complex biological matrix. The proposed methodology detects traces of spiked 5HT in human serum with a limit of detection (LOD) of 3.83 ng mL-1 corresponding to the Raman marker band (indole in-phase ring breathing) at 745 cm-1. The LOD is well below the normal physiological range of 5HT in human serum (101-283 ng mL-1). Such high sensitivity is particularly advantageous for identifying small but biologically meaningful fluctuations in the 5HT levels. This study thus highlights the practical applicability of the proposed nanosubstrate for biomedical analysis with successful validation in spiked human serum along with satisfactory recovery and precision.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CRISPR-enabled ultrasensitive surface-enhanced Raman scattering sensing platform for background-free detection of phosphorylated tau in Alzheimer's disease.Biosensors & bioelectronics · 2026
- Sandwich SERS Chip with Raman‑Silent Reporters for Ultrasensitive Serum Cortisol Detection and Depression Differentiation.ACS sensors · 2026
- An AuNF-modified optical fiber LSPR biosensor for sensitive and wide-range 5-HT detection.Analytical methods : advancing methods and applications · 2026
- A Plasmonic Nanopore Sensor for Dual-Gating Optoelectronic Detection of Cysteine.Small methods · 2026
- Surface-enhanced Raman scattering spectroscopy of human cerebrospinal fluid: protocol selection and biomolecular interpretation.Analytical and bioanalytical chemistry · 2026
- Self-calibrated SERS nanoprobe with an α-ketoamide caged switch for tracking peroxynitrite dynamics in living cells.Talanta · 2026