ZnO-Pd nanobolts-based immunoanalytical detection of a pancreatic cancer biomarker and its software-assisted digital quantification.
Akanksha Deshwal, Rajesh, Sang J Chung, Prashant Mishra, Ravi Mani Tripathi
Amity Institute of Nanotechnology, Amity University Uttar Pradesh (AUUP), Noida-201313, India. rmtripathi@amity.edu. · CSIR-National Physical Laboratory, New Delhi, India.
Key points
From the paper's conclusion- Software-assisted signal processing enabled precise assessment of the limit of detection (LOD) of 0.000359 U mL-1 and the limit of quantification (LOQ) of 0.00108 U mL-1.
Abstract
Early and reliable detection of pancreatic cancer (PC) remains a formidable clinical challenge, largely owing to the limited sensitivity, operational unreliability, and enzyme dependence of existing carbohydrate antigen 19-9 (CA19-9) immunoassays. In this work, we determine for the first time that ZnO-Pd nanobolts show intrinsic oxidase-like activity. Furthermore, this attribute was used to fabricate a colorimetric immunoanalytical sensor based on nanozymes for the sensitive and specific detection of CA19-9, a biomarker for PC. In this research, immunoreagent optimization, smartphone-assisted signal analysis, and kinetic analysis of nanozyme catalytic activity were employed to enable highly sensitive detection of CA19-9. Enzyme-kinetic studies showed low Michaelis-Menten constants (KM) of 0.99 mM, as well as high turnover numbers (kcat) and catalytic efficiencies (kcat/KM) of 4.48 × 10-4 s-1 and 0.453 M-1 s-1, respectively, indicating high substrate affinity. The optimized nanozyme was functionalized with Goat anti-mouse IgG (GAM IgG), thereby facilitating antigen recognition and signal transduction. The proposed immunoassay demonstrated high analytical sensitivity (LOD of 0.000159 U mL-1 and LOQ of 0.000482 U mL-1) and exceptional selectivity even in complex biological matrices. Software-assisted signal processing enabled precise assessment of the limit of detection (LOD) of 0.000359 U mL-1 and the limit of quantification (LOQ) of 0.00108 U mL-1. The practical utility of the fabricated immunoassay was further examined using human serum, with recovery rates ranging from 100.6% to 102%, indicating high accuracy and reproducibility. Furthermore, the successful digitalization of assay results into software-based readable data demonstrates the sensing approach's potential for portable, cost-effective, and point-of-care PC diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cu/SiO2 nanozyme-amplified colorimetric immunosensor for high-fidelity pancreatic cancer detection with software-assisted evaluation.Analytical methods : advancing methods and applications · 2026
- Visible-light-activated CdS/Ag₂S/g-C₃N₄ nanozyme for sensitive colorimetric detection of carbohydrate antigen19-9.Mikrochimica acta · 2026
- Exogenous-Label-Free Colorimetric/SERS Dual-Mode Immunosensing Platform Driven by Au NCs@Pt Nanozyme for Ultrasensitive and Rapid Detection of the Pancreatic Cancer Biomarker CA19-9Analytical Chemistry · 2026
- Cu-Trp nanoparticle mimetic enzyme-based colorimetric immunoassay for CA19-9 detection.Analytical methods : advancing methods and applications · 2026
- Heterovalent Co Doping Boosts the Phosphatase-like Activity of UiO-66-NH₂ for Ultrasensitive Fluorescence Immunoassay of CEAAnalytical Chemistry · 2025
- Magnetic and Peroxidase‐Specific Single‐Atom Nanozyme Through Cu‐Doping Engineering for Ultrasensitive and Visual Tumor DiagnosisAngewandte Chemie International Edition · 2025