Lab on a chip

A rapid point-of-care detection system for OVA-specific IgG and IgE utilizing a rotational SlipChip.

Honglin Lu, Yifan Jia, Jianxia Wang, Zixuan Song, Di Wu, Bei Wang, Wenxin Zhang, Fang Yang

Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, School of Life Sciences, Jilin University, Changchun 130012, China. fangyang@jlu.edu.cn. · Department of Pathology, The First Hospital of Jilin University, Changchun, 130021, China. zhangwenxin@jlu.edu.cn.

Key points

From the paper's conclusion
  • Therefore, the rr-SlipChip introduces a new rotational sliding microfluidic architecture distinct from conventional SlipChip designs, providing a novel platform for rapid, sensitive, continuous, and scalable in vitro allergen diagnosis with significant potential for point-of-care testing (POCT) and accessible precision allergy management.

Abstract

Allergic diseases affect approximately 22% of the global population. Rapid and accurate identification of causative allergens is essential for enabling timely clinical intervention and preventing re-exposure. Current clinical approaches for in vivo allergen diagnosis often involve risks associated with direct allergen exposure, while many existing in vitro diagnostic methods remain labor-intensive, time-consuming, and technically demanding. For example, the basophil activation test requires sophisticated instrumentation and specialized operational expertise. Therefore, there is an urgent need for a convenient, rapid, sensitive, and easily assembled platform for reliable in vitro allergen diagnosis while reducing reliance on sample pretreatment, auxiliary instrumentation, and external control systems. In this study, a disc-shaped microfluidic device, termed the relative rotation SlipChip (rr-SlipChip), was developed. Unlike conventional SlipChip platforms that depend on precise microstructural alignment, the rr-SlipChip employs radial alignment and step-by-step rotation to enable convenient configuration of loading pathways for multiple immunoreagents. In addition, the reagent pathways are completely isolated from one another, thereby minimizing the risk of cross-contamination. Using a single rotary pneumatic control channel combined with a simple sliding operation, the proposed device enables immunoassays to be completed within approximately 25-37 min. The rr-SlipChip achieves favorable analytical sensitivity, with limits of detection of 0.614 ng mL-1 for sIgG and 0.689 ng mL-1 for sIgE. Therefore, the rr-SlipChip introduces a new rotational sliding microfluidic architecture distinct from conventional SlipChip designs, providing a novel platform for rapid, sensitive, continuous, and scalable in vitro allergen diagnosis with significant potential for point-of-care testing (POCT) and accessible precision allergy management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.