Lab on a chip

Development of biomimetic microfluidic device to study complex flow in small intestines by decoupling geometric determinants.

Kazuki Komatsu, Yuto Shiraiwa, Satoru Kuriu, Naoyuki Yamamoto, Tadashi Ishida

Department of Mechanical Engineering, School of Engineering, Institute of Science Tokyo, Kanagawa 226-8501, Japan. komatsu.k.a4a9@m.isct.ac.jp. · Department of Mechanical Engineering, School of Science and Technology, Ritsumeikan University, Shiga 525-8527, Japan.

Key points

From the paper's conclusion
  • We present a biomimetic microfluidic device that experimentally decouples three static and dynamic determinants governing flow in the small intestine: villus-like structures, channel height, and dynamic wall deformation associated with intestinal motility.

Abstract

We present a biomimetic microfluidic device that experimentally decouples three static and dynamic determinants governing flow in the small intestine: villus-like structures, channel height, and dynamic wall deformation associated with intestinal motility. Although these three factors jointly influence luminal transport in vivo, their individual contributions are difficult to quantify because they are intrinsically coupled in native tissue. To enable such quantification, the device incorporates villus-like structures, a tunable channel height, and pneumatically driven wall deformation, allowing these determinants to be independently controlled or combined while reproducing selected geometric features of intestinal architecture. To characterize particle transport in the device, we measured particle displacements in the axial (x) and lateral (y) directions of the channel and quantified their variability using standard deviations. Particle-tracking experiments showed that villus-like structures increased the lateral particle displacement standard deviation (σy). In the presence of villus-like structures, reducing the channel height increased particle displacement in the x direction and σy, although the data did not establish an increase in σy normalized by the mean absolute axial displacement. Dynamic wall deformation increased σy by up to 9.4-fold, and statistically significant increases were detected only at the two smallest channel heights. Under conditions selected to match the channel height of native mouse small-intestinal tissue, σy was of the same order of magnitude as that observed in a microfluidic device in which native tissue forms the flow channel. No statistically significant difference was detected in this comparison.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development of biomimetic microfluidic device to study complex flow in small intestines by decoupling geometric determinants — Science Skim