Real-time integrated and multiplexed electrochemical sensor for reactive oxygen species in a high-throughput microphysiological system.
William C Records, Brian P Cain, Norman F Sheppard, Michael J Matranga, Carlos A Segura, Cáit Ní Chléirigh, Anthony J Quinnert, WeiXuan Lai,
Division of Microsystems and Advanced Materials, The Charles Stark Draper Laboratory, 555 Technology Square, Cambridge, MA, 02139, USA. · Division of Bioengineering, The Charles Stark Draper Laboratory, 555 Technology Square, Cambridge, MA, 02139, USA. hazizgolshani@draper.com.
Key points
From the paper's conclusion- In this work, we have integrated a 96-plex, real-time ROS measurement system into PREDICT96, a high-throughput MPS platform, as a first demonstration of a highly multiplexed electrochemical sensor capability.
Abstract
The integration of real-time sensors in microphysiological systems (MPS) faces steep challenges due to the mass transport limitations inherent to microfluidic environments, complex microdevice fabrication methods, and maintenance of long-term performance at high throughput. Reactive oxygen species (ROS) represent attractive yet elusive sensing targets for MPS due to their integral role in cellular metabolism, oxidative homeostasis, and response to disease and injury. Nevertheless, without real-time measurement, their short-lived nature limits practical investigations of ROS as biomarkers in biomedical research. In this work, we have integrated a 96-plex, real-time ROS measurement system into PREDICT96, a high-throughput MPS platform, as a first demonstration of a highly multiplexed electrochemical sensor capability. The ROS measurement system comprises a miniaturized amperometric sensor array capable of rapidly measuring H2O2, a prototypical ROS, at micromolar concentrations (1-10 μM) with high sensitivity and selectivity across 96 microphysiological devices. Integrated microfluidic pumping enables active mixing during measurement and supports the detection of targets with low concentrations or short lifetimes. This novel capability will enable future work investigating ROS as biomarkers for disease modeling and medical countermeasure evaluation, targeting viral respiratory infections of lung-immune tissue models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metal nanocluster platforms for reactive oxygen species sensing: Core-ligand design, signal transduction pathways, and analytical bottlenecks.Talanta · 2026
- Dynamic energy metabolism physiological biosensing via integrated sensitive bivariate sensors and electronics for in situ monitoring of scalable cell models.Biosensors & bioelectronics · 2026
- Miniaturized optical readout of genetically encoded sensors for real-time oxidative stress monitoring in cell and animal modelsFrontiers in Sensors · 2026
- MetaboSense: An Integrated Quantum Dot-Mediated Aptamer Assay and Modular Microfluidic Platform for Continuous In-Line Monitoring of Lung Metabolism During Ex Vivo Perfusion.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Liquid-Suspendable Metabolic Sensors Allow Real-Time Oxygen Consumption Monitoring in Caco-2 and Colon Organoid-Based Gut-on-a-Chip Models.Biotechnology journal · 2026
- Advances in reactive oxygen species detection across biological systems with relevance to postharvest researchScientia Horticulturae · 2025