A hand-powered positive pressure-driven sample injection digital RPA-CRISPR-Cas12a chip.
Mengda Liang, Xutong Shi, Dexiong Xia, Wen Zong, Haiqin Hu, Ningkang Xie, Yulai Li, Shaowu Lv,
Zhejiang Key Laboratory of Quantum Materials and Control, School of Information and Electrical Engineering, Hangzhou City University, Hangzhou, 310015, Zhejiang Province, China.
Key points
From the paper's conclusion- This study proposed a hand-powered positive pressure-driven sample injection digital RPA-CRISPR-Cas12a chip for on-site food-safety testing.
Abstract
Chamber-based digital nucleic acid assays allow absolute quantification with high analytical sensitivity. However, sample introduction and digital discretization mainly rely on negative pressure drive, and this injection method limits its application, especially in on-site detection. But their use outside laboratory settings is still limited by the way samples are partitioned, which often depends on vacuum systems, centrifugation or specialized actuation. Positive-pressure loading is simple and well suited to portable operation, yet it is difficult to apply directly to chamber-based digital assays because air backflow and sample trailing can disrupt stable compartmentalization. This study proposed a hand-powered positive pressure-driven sample injection digital RPA-CRISPR-Cas12a chip for on-site food-safety testing. In this study, the two problems were addressed by combining photocurable oil fixation with branch-channel optimization, enabling rapid and stable discretization in a 15 120 chamber-based microfluidic digital chip using only a hand-operated syringe. Sample loading and partitioning were completed within 2 min without vacuum or centrifugal loading equipment. After integration with a one-pot digital RPA-CRISPR-Cas12a assay targeting hlyA, the system achieved absolute quantification of Listeria monocytogenes with a detection limit of 100 copies μL-1 and good linearity across dilutions (R2 = 0.99973). The tests conducted on the milk samples containing the standard substances further proved that this method could be used for on-site testing under resource-limited conditions. Overall, this study provides a feasible strategy for implementing positive-pressure digitization in a portable chamber-based digital microfluidic system, which expands the utility of chamber-based digital assays for portable and instrument-free on-site food-safety testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasensitive Detection of Multiple Foodborne Pathogens Using CRISPR–Cas12a on a Finger-Actuated Microfluidic Device Integrated with a Modular Pressurizing PumpAnalytical Chemistry · 2025
- Dual proximity-activated immuno-LAMP-CRISPR for ultrasensitive protein detection on an integrated microfluidic chip.Biosensors & bioelectronics · 2026
- Amplification-Free CRISPR-Cas System Integrated Centrifugal Digital Microfluidic Platform Developed for Multiplexed Respiratory Pathogen Nucleic Acid AnalysisAnalytical Chemistry · 2025
- PAM-Free Programmable Enzymatic Cascade Design Enabling Highly Sensitive CRISPR/Cas12a Lateral Flow Assay for Foodborne Pathogen Detection.Analytical chemistry · 2026
- A Droplet-Free and Oil-Free Microfluidics Based on Self-Pumping Hydrogel for Point-of-Care Multiplex Digital Nucleic Acid DetectionAnalytical Chemistry · 2026
- CRISPR/Cas12a-Based Dynamic Light Scattering Assay for Nucleic Acid Amplification-Free and Ultrasensitive Detection of Listeria monocytogenesAnalytical Chemistry · 2025