Modelling and simulation of species transport in capillary-fed electrolysis cells.
Marco De Paoli, Jeffery A Wood, Albertus W Vreman, Dominik Krug
Institute of Fluid Mechanics and Heat Transfer, TU Wien, Getreidemarkt 9, Wien 1060, Austria. · Soft Matter, Fluidics and Interfaces, MESA+ Institute for Nanotechnology, J. M. Burgers Centre for Fluid Dynamics, University of Twente, Enschede 7500 AE, Netherlands.
Key points
From the paper's conclusion- This appeared to allow continuous operation without exceeding solubility limits for the maximum simulation time of 5 hours at 0.4 A cm-2, similar to what was achieved experimentally.
Abstract
In so-called capillary-fed electrolysis cells (Hodges et al., Nature Commun., 2022, 13, 1304), electrolyte is resupplied through capillary forces in a porous structure contained between the two electrodes. This configuration enables largely bubble-free operation, resulting in low cell potentials even at high current densities, and this approach is therefore highly promising for terrestrial as well as space applications. While sustained operation has been demonstrated experimentally, the mechanism enabling this remains unclear, especially given the expected rise in electrolyte concentration over time and the risk of salt precipitation in the porous separator. In this study, our goal is to identify possible mechanisms that could act to limit the maximum electrolyte concentration in the separator. To this end, we present a one-dimensional model for the electrolyte transport in the porous separator, based on which we evaluate the limits of capillary feeding as a function of electrode size, properties of the porous structure, and current density. Our estimates suggest that any potential diffusio-osmotic effect remains negligible in the present setup, and no stable operation seems possible within solubility limits at meaningful electrode sizes and current densities within the 1D model. Three-dimensional simulations of fluid flow and mass transport for a 1 cm2 electrode on a larger separator, performed using COMSOL Multiphysics, demonstrate that allowing diffusion in all spatial directions significantly enlarges the stable operating window, while buoyancy has only a very limited effect in the present configuration. Simulations accounting for solutal Marangoni effects at the separator surface indicate that the resulting Marangoni stresses are sufficiently strong to induce a recirculating flow within the separator, thereby lowering the maximum electrolyte concentration in the electrode region. This appeared to allow continuous operation without exceeding solubility limits for the maximum simulation time of 5 hours at 0.4 A cm-2, similar to what was achieved experimentally.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting and extending the bubble-free operating limit of capillary-fed water electrolysisarXiv · 2026
- Liquid-Phase Connectivity in Porous Membranes Enables High-Rate Acidic Zero-Gap CO2 ElectrolysisNano Letters · 2026
- Computational Fluid Dynamics Reveals Mass Transfer Limitations in a Pilot‐Scale Microbial Electrolysis CellWater Environment Research · 2026
- Convection can enhance the capacitive charging of porous electrodesProceedings of the National Academy of Sciences · 2025
- Gas Retention in Porous Cathodes Governs Bicarbonate Electrolysis PerformanceACS Energy Letters · 2026
- Water transport model for cathode-vapour-feed electrolysers.Faraday discussions · 2026