Faraday discussions

Characteristics of gas bubble discharge from different PTLs of PEM water electrolysis under microgravity.

Mizuho Muraki, Naoya Osawa, Ichika Hida, Yui Ishimori, Ibuki Sato, Mikito Ueda, Hisayoshi Matsushima, Mizuki Shinoda,

Graduate School of Engineering, Hokkaido University, Kita 8, Nishi 5, Kita-ku, Sapporo-shi, Hokkaido, Japan. matsushima@eng.hokudai.ac.jp. · Honda R&D Co., Ltd, 4630 Shimotakanezawa, Haga-machi, Haga-gun, Tochigi, Japan.

Key points

From the paper's conclusion
  • The results show that the onset of bubble evolution under µG was significantly slower than that under 1Gravity (G).

Abstract

Under microgravity (µG) electrolysis tests were conducted using a drop tower (COSMOTORRE in Hokkaido, Japan) to investigate the bubble evolution characteristics of proton exchange membrane (PEM) water electrolysis. Several types of porous transport layers (PTLs) and electrolysis conditions were investigated. The bubble dynamics on the PTL surface were directly observed by a high-speed camera and analyzed by an in-house image-processing program. The results show that the onset of bubble evolution under µG was significantly slower than that under 1Gravity (G). The bubble behavior released from the PTLs also differed under 1G and µG. However, once the oxygen bubble began to evolve continuously, the evolution rate was equivalent in both environments. The delay in the onset of bubble evolution under µG became more significant at low current densities. This was because it took longer for the gas to fill the internal PTL structures. Tests with different types of PTL revealed that the structure and thickness had a minimal effect. In contrast, the internal volume characteristics, such as porosity and volume-average pore diameter, was attributed to slow the onset of bubble evolution. Based on these results, the transport mechanism under µG are discussed. In the absence of buoyancy, the generated gas progressively accumulated inside the PTL pores. Eventually, the gas was expelled into the flow channel as newly formed bubbles. This transport mechanism implied that the delay in evolution highly effected how long the oxygen was held inside the PTL under µG. This accumulated gas could be a risk to performance degradation during long-term water electrolysis in space.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Characteristics of gas bubble discharge from different PTLs of PEM water electrolysis under microgravity — Science Skim