Optimisation of measurement and data analysis of time-resolved X-ray absorption spectroscopy of thin film organic semiconductors.
Belen Alonso-Garcia, Miguel M Manresa-Nalda, Oliver G Alexander, Kaiyu Hu, Felix S Egun, Zachery Donnellan, Joseph J Broughton, Jacob P Lee,
Blackett Laboratory, Prince Consort Road, London, SW7 2BW, UK. m.matthews@imperial.ac.uk. · Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
Key points
From the paper's conclusion- These results demonstrate that reliable soft X-ray TR-XAS requires the joint optimisation of experimental design and statistical inference, providing a practical framework for extracting robust observables from low-signal XFEL measurements in dose-limited regimes.
Abstract
Time-resolved X-ray absorption spectroscopy (TR-XAS) at X-ray free-electron lasers enables element-specific probing of ultrafast dynamics, but soft X-ray measurements are often limited by low fluorescence yield, strong shot-to-shot fluctuations, and radiation damage in organic thin films. Here, we present a unified framework combining analytical signal-to-noise ratio (SNR) modelling with regression-based analysis for fluorescence-detected soft X-ray absorption spectroscopy. The SNR model predicts fundamentally different optimal conditions for static and transient measurements, with transient experiments requiring thin films (∼80-100 nm) and substantially higher photon counts. We apply this framework to shot-resolved total fluorescence yield XAS measurements of the non-fullerene acceptor Y6 at the nitrogen K-edge using a high-repetition-rate XFEL source, comparing low-dose and intermediate-dose regimes relevant to transient and static measurements, respectively. A calibration-based flux reconstruction systematically improves the fluorescence-flux correlation, while the dominant improvement arises from reformulating XAS extraction as a shot-resolved regression problem. Compared to the conventional ratio-of-means estimator, the regression-based estimator reduces the run-to-run spectral variability by up to a factor of ∼4.4 in the low-dose regime most relevant for transient measurements. Residual-based outlier rejection was found to systematically degrade reproducibility, indicating that the tails of the shot distribution primarily reflect intrinsic XFEL fluctuations rather than detector artefacts. These results demonstrate that reliable soft X-ray TR-XAS requires the joint optimisation of experimental design and statistical inference, providing a practical framework for extracting robust observables from low-signal XFEL measurements in dose-limited regimes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimizing MHz X-ray photon correlation spectroscopy with burst-mode free-electron laser operationarXiv · 2026
- Shot-noise-limited X-ray powder diffraction from organic crystals with laser-driven femtosecond X-ray source.Journal of applied crystallography · 2026
- Probing Hot Carrier Generation Efficiency in Low-Concentration Plasmonic Gold Nanoparticles via XFEL X-ray Absorption SpectroscopyThe Journal of Physical Chemistry C · 2026
- Microsecond X-ray reflectometry.Journal of applied crystallography · 2026
- Multivariate curve resolution for X-ray absorption spectroscopy data interpretation: Best practices and limitationsRadiation Physics and Chemistry · 2026
- Mitigating X-ray-Induced Damage in CD-SAXS Metrology of EUV Resists.ACS applied materials & interfaces · 2026