Dalton transactions (Cambridge, England : 2003)

New insights into AE-DAPhen for the selective separation of americium: lanthanide behaviour and performance in simulated PUREX raffinate.

Lara Bruneel, Filip Kolesar, Yong Qiang Wan, Pavle Mocilac, Tomas Opsomer, Thomas Cardinaels, Wim Dehaen, Karen Van Hecke

Nuclear Energy Technology (NET), Belgian Nuclear Research Centre (SCK CEN), 2400 Mol, Belgium. karen.van.hecke@sckcen.be. · School of Nuclear Science and Technology, Lanzhou University, 730000, China. pavlem@lzu.edu.cn.

Key points

From the paper's conclusion
  • Experiments with a more complex matrix, using a simulated PUREX highly active raffinate, produced overall higher distribution ratios and shifted the stripping conditions to lower acidity, giving SFCm/Am = 3.4 and SFEu/Am = 57 at 0.4 mol L-1 HNO3.

Abstract

Selective separation of americium from highly active raffinates of the PUREX process remains one of the most demanding challenges in advanced fuel reprocessing, particularly due to the chemical similarity between americium and curium. Recently, the CHON-compliant hydrophilic ligand AE-DAPhen (N,N'-bis(2-(2-hydroxyethoxy)ethyl)-1,10-phenanthroline-2,9-dicarboxamide) was proposed as a promising candidate for Am-selective stripping in AmSel-type solvent extraction systems. In this study, a validation of this system is provided using single-vial solvent extraction experiments containing 241Am, 244Cm and 152Eu tracers, quantified by combined α- and γ-spectrometry to eliminate tube-to-tube uncertainties inherent to the LSC-based method. In the TODGA system, stripping conditions were obtained with 10 mmol L-1 AE-DAPhen in 1.0 mol L-1 HNO3, giving SFCm/Am = 4.5 and SFEu/Am = 237, and with 5 mmol L-1 AE-DAPhen in 0.75 mol L-1 HNO3, giving SFCm/Am = 4.4 and SFEu/Am = 196. Complementary tests showed very high aqueous solubility of AE-DAPhen and limited degradation in acidic conditions. ICP-MS measurements revealed that the distribution ratios of the light lanthanides La(III), Ce(III) and Pr(III) approach those of Am(III), resulting in light-lanthanide co-stripping. Experiments with a more complex matrix, using a simulated PUREX highly active raffinate, produced overall higher distribution ratios and shifted the stripping conditions to lower acidity, giving SFCm/Am = 3.4 and SFEu/Am = 57 at 0.4 mol L-1 HNO3. Increased competition for AE-DAPhen at higher metal loading may contribute to these changes. Combinations with the unsymmetrical DGAs, PnDdDGA and iPDdDGA, retained Cm/Am selectivity but substantially altered metal partitioning and the conditions required for stripping. Stripping conditions for iPDdDGA were approached at 30 mmol L-1 AE-DAPhen in 0.25 mol L-1, giving SFCm/Am = 4.9 and SFEu/Am = 467. These results provide new insight into how the influence of matrix composition and ligand-extractant combinations modulates AE-DAPhen-based separations, while showing that Cm/Am selectivity is largely retained and that light-lanthanide co-stripping remains an important limitation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

New insights into AE-DAPhen for the selective separation of americium: lanthanide behaviour and performance in simulated PUREX raffinate — Science Skim