Physical chemistry chemical physics : PCCP

Multiscale simulation with a physics-informed surrogate for HfO2 atomic layer deposition in multilayer pillar-array nanostructures.

Zhang Liu, Yanwei Wen, Yuqun Feng, Yiao Ge, Yuan Gao, Qiyuan Ruan, Hongliang Lü, Fangzhou Yu,

School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China. rongchen@mail.hust.edu.cn. · School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China. bshan@mail.hust.edu.cn.

Computational

Key points

From the paper's conclusion
  • We develop a multiscale framework that couples reactor-scale computational fluid dynamics with nanostructure-scale Knudsen diffusion and closes the surface reaction with a physics-informed surrogate model built from kinetic Monte Carlo data.

Abstract

Conformal HfO2 atomic layer deposition (ALD) in multilayer pillar-array (MPA) nanostructures depends on precursor transport across reactor and feature scales, yet direct coupling to atomistic kinetics is prohibitively expensive. We develop a multiscale framework that couples reactor-scale computational fluid dynamics with nanostructure-scale Knudsen diffusion and closes the surface reaction with a physics-informed surrogate model built from kinetic Monte Carlo data. Symbolic regression is used to express the parameters of the surrogate as explicit functions of the precursor concentration, keeping the transient three-dimensional coupled calculation tractable. Applied to an idealized ten-layer MPA unit cell, the model resolves the evolution of concentration, coverage, and reaction rate. Residual precursor redistributes during the hold without additional input, and the coefficient of variation (CV) of the coverage across the pillar surfaces decays exponentially with a time constant of 0.3 s toward a dose-limited asymptote. A systematic scan of pulse durations and flow rates shows a saturating dependence of the pulse-end coverage on the precursor dose. For pulses near 2 s under the production parameter set, a CV below 5% is obtained at a dose of 500 sccm s on the tested flow grid. The 50%-coverage front advances by one layer every 0.13-0.20 s under the tested flows, corresponding to an incremental nominal dose of 40-53 sccm s per layer. The minimum dose required for 95% uniformity scales with the process time t as t-0.36 within the sampled domain. Pareto analysis identifies a 2.0 s, 250 sccm pulse followed by a 0.5 s hold as a balanced operating condition. The framework links atomistic kinetics to reactor operation and provides simulation-derived guidance for ALD process design.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers