Tip-sample distance dependence of local work function in Kelvin probe force microscopy on Pb/Si(111) islands.
Daniel Rothhardt, Thomas Späth, Paul P Schmidt, Ralf Metzler, Regina Hoffmann-Vogel
Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Str. 24-25, 14476 Potsdam, Germany. hoffmannvogel@uni-potsdam.de. · Physikalisches Institut, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany.
Key points
From the paper's conclusion- We investigate how the CPD changes as a function of tip-sample distance and how the electrostatic force changes as a function of the applied bias between the tip and the sample.
Abstract
To gain a better understanding of the Kelvin probe force microscopy (KPFM) method, it is important to obtain a quantitative understanding of the measured contact potential difference (CPD) values as a function of the tip-sample distance. This will allow a more complete quantitative understanding of the electronic properties and the forces acting on the tip. Here, we chose Pb islands on a Si(111) 7 × 7 surface, metallic islands on a semiconducting surface. Using a scanning force microscope in frequency modulation mode, we perform point bias-approach measurements at 120 K on Pb islands. We investigate how the CPD changes as a function of tip-sample distance and how the electrostatic force changes as a function of the applied bias between the tip and the sample. The measured distance-dependence of the CPD not only allows a connection between the point-of-view of atomic resolution KPFM and of the averaging effects of the body of the tip but also allows the investigation of the shape of charged objects on the surface.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Method to Reconstruct Charge Density Distribution on Dielectric Surfaces Using Kelvin Probe Force Microscopy.The journal of physical chemistry. A · 2026
- Precise Measurement of Piezoelectric Response With Interferometric Piezoresponse Force Microscopy.Small methods · 2026
- Methodology to characterize physical properties of electrode/dielectric interfaces using sub-micrometer-scale measurements.Nanotechnology · 2026
- Native Defects Enable Facile Measurement of the Carrier Concentration in Two-Dimensional Semiconductors Using Kelvin Probe Force Microscopy.Nano letters · 2026
- Identifying Contact Barrier Types in Few-Layer MoS2 Devices Using Correlative IV, LBIC, and Bias-Dependent KPFM.ACS applied materials & interfaces · 2026