Chemical communications (Cambridge, England)

Determination of plasticizers in prepared dishes using Al(OH)(1,4-ndc)-based dispersive solid-phase extraction coupled with UHPLC-MS/MS.

Xiao Liang, Fan Liu, Haifeng Wei, Yan Zhang, Cheng Rui, Lan Guo, Wenbin Zhong, Yiqun Wan

Jiangxi Province Key Laboratory of Drug Target Discovery and Validation, School of Chemistry and Chemical Engineering, Nanchang University, Nanchang, 330031, People's Republic of China. guolan@ncu.edu.cn. · Center of Analysis and Testing, Nanchang University, Nanchang, 330031, People's Republic of China.

Key points

From the paper's conclusion
  • An Al(OH)(1,4-ndc)-based d-SPE coupled with UHPLC-MS/MS method was developed to quantify five emerging plasticizers in prepared dishes, achieving LOQs of 0.24-3.41 µg L-1 and recoveries of 77.0-99.0%.

Abstract

An Al(OH)(1,4-ndc)-based d-SPE coupled with UHPLC-MS/MS method was developed to quantify five emerging plasticizers in prepared dishes, achieving LOQs of 0.24-3.41 µg L-1 and recoveries of 77.0-99.0%. Real-sample analysis revealed matrix-dependent contamination, with high-fat dishes exhibiting significantly higher plasticizer levels than low-fat counterparts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Determination of plasticizers in prepared dishes using Al(OH)(1,4-ndc)-based dispersive solid-phase extraction coupled with UHPLC-MS/MS — Science Skim